Your browser doesn't support javascript.
loading
Endothelial-dependent vasomotion in a coronary segment treated by ABSORB everolimus-eluting bioresorbable vascular scaffold system is related to plaque composition at the time of bioresorption of the polymer: indirect finding of vascular reparative therapy?
Eur Heart J ; 33(11): 1325-33, 2012 Jun.
Article em En | MEDLINE | ID: mdl-22507972
ABSTRACT

AIMS:

To analyse the vasoreactivity of a coronary segment, previously scaffolded by the ABSORB bioresorbable vascular scaffold (BVS) device, in relationship to its intravascular ultrasound-virtual histology (IVUS-VH) composition and reduction in greyscale echogenicity of the struts. Coronary segments, transiently scaffolded by a polymeric device, may in the long-term recover a normal vasomotor tone. Recovery of a normal endothelial-dependent vasomotion may be enabled by scaffold bioresorption, composition of the underlying tissue, or a combination of both mechanisms. METHODS AND

RESULTS:

All patients from the ABSORB Cohort A and B trials, who underwent a vasomotion test and IVUS-VH investigation at 12 and 24 months, were included. Acetylcholine (Ach) and nitroglycerin were used to test either the endothelial-dependent or -independent vasomotion of the treated segment. Changes in polymeric strut echogenicity-a surrogate for bioresorption-IVUS-VH composition of the tissue underneath the scaffold and their relationship with the pharmacologically induced vasomotion were all evaluated. Overall, 26 patients underwent the vasomotion test (18 at 12 and 8 at 24 months). Vasodilatory response to Ach was quantitatively associated with larger reductions over time in polymeric strut echogenicity (y= -0.159x- 6.85; r= -0.781, P< 0.001). Scaffolded segments with vasoconstriction to Ach had larger vessel areas (14.37 ± 2.50 vs. 11.85 ± 2.54 mm(2), P= 0.030), larger plaque burden (57.31 ± 5.96 vs. 49.09 ± 9.10%, P= 0.018), and larger necrotic core (NC) areas [1.39 (+1.14, +1.74) vs. 0.78 mm(2) (+0.20, +0.98), P= 0.006] compared with those with vasodilation.

CONCLUSION:

Vasodilatory response to Ach, in coronary segments scaffolded by the ABSORB BVS device, is associated with a reduction in echogenicity of the scaffold over time, and a low amount of NC. In particular, the latter finding resembles the behaviour of a native coronary artery not caged by an intracoronary device.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasodilatação / Isquemia Miocárdica / Vasos Coronários / Sirolimo / Placa Aterosclerótica / Imunossupressores Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasodilatação / Isquemia Miocárdica / Vasos Coronários / Sirolimo / Placa Aterosclerótica / Imunossupressores Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article