Defining the impact of maternal cell contamination on the interpretation of prenatal microarray analysis.
Lamb, Allen N; Rosenfeld, Jill A; Coppinger, Justine; Dodge, Erin T; Dabell, Mindy Preston; Torchia, Beth S; Ravnan, J Britt; Shaffer, Lisa G; Ballif, Blake C.
Afiliação
  • Lamb AN; 1] Signature Genomic Laboratories, PerkinElmer, Inc., Spokane, Washington, USA.
Genet Med ; 14(11): 914-21, 2012 Nov.
Article em En | MEDLINE | ID: mdl-22766610
ABSTRACT

PURPOSE:

To understand the ability of microarray-based comparative genomic hybridization to detect copy-number variation in the presence of maternal cell contamination.

METHODS:

To simulate maternal cell contamination, normal female DNA was mixed at various levels with DNA carrying known copy-number variations. Mixtures were run on a whole-genome 135K oligonucleotide-based array. Data were analyzed with custom analysis software.

RESULTS:

The array and software design allowed detection of larger copy-number variations at higher levels of maternal cell contamination than smaller copy-number variations. The smallest duplications and deletions were obscured at 22-31% and 55-58% maternal cell contamination, respectively. With male fetal samples, the sex chromosome ratios started showing observable shifts at ~10% maternal cell contamination.

CONCLUSION:

As knowledge of the maternal cell contamination level aids in interpretation of array results, we recommend concurrent, independent maternal cell contamination studies for all fetal samples for accurate and timely results. With male fetal samples in our laboratory, interfering levels of maternal cell contamination can be excluded when the sex chromosome plots appear normal. Thus, reportable male microarray-based comparative genomic hybridization results may be occasionally achieved without maternal cell contamination studies. Because the effects of maternal cell contamination on microarray results are dependent on array platforms, experimental techniques, and software algorithms, each laboratory should perform its own analysis to determine acceptable levels of maternal cell contamination for its assays.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico Pré-Natal / Software / Análise de Sequência com Séries de Oligonucleotídeos / Hibridização Genômica Comparativa Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Pregnancy Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico Pré-Natal / Software / Análise de Sequência com Séries de Oligonucleotídeos / Hibridização Genômica Comparativa Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Pregnancy Idioma: En Ano de publicação: 2012 Tipo de documento: Article