Your browser doesn't support javascript.
loading
Central-peripheral temperature gradient: an early diagnostic sign of late-onset neonatal sepsis in very low birth weight infants.
Leante-Castellanos, José Luis; Lloreda-García, José M; García-González, Ana; Llopis-Baño, Caridad; Fuentes-Gutiérrez, Carmen; Alonso-Gallego, José Ángel; Martínez-Gimeno, Antonio.
Afiliação
  • Leante-Castellanos JL; Section of Neonatology, Service of Pediatrics, Hospital General Universitario Santa Lucía, Cartagena, Murcia, Spain. leantejl@yahoo.es
J Perinat Med ; 40(5): 571-6, 2012 Apr 22.
Article em En | MEDLINE | ID: mdl-22945277
ABSTRACT

AIMS:

We assessed central-peripheral temperature gradient alteration for the diagnosis of late-onset neonatal sepsis and compared earliness detection of this sign with altered blood cell count and C-reactive protein.

METHOD:

Thirty-one preterm babies (<1500 g or <32 weeks) participated in an observational prospective study. Axillary (central) and sole (peripheral) temperatures were continuously monitored with a thermal probe (ThermoTracer; Dräger Medical AGF & Co. KgaA, Lübeck, Germany) adjusting incubator air temperature for a thermal gradient <1.5°C. Central-peripheral temperature alteration was defined as a thermal gradient >2°C that could not be corrected with protocolized air temperature modifications. Proven (positive blood culture) sepsis and probable late-onset sepsis were recorded.

RESULTS:

Late-onset sepsis was diagnosed in 11 neonates (proven, 9; probable, 2). Thermal gradient alteration was present in 12 cases, in association with the onset of sepsis in 10 and concomitantly with a ductus arteriosus and stage 1 necrotizing enterocolitis in 2. Thermal gradient alteration had a sensitivity of 90.9% [95% confidence interval (CI), 62.3-98.4] and specificity of 90% (95% CI, 69.9-97.2%), and in 80% of cases, it occurred before abnormal laboratory findings.

CONCLUSIONS:

Central-peripheral temperature gradient monitoring is a feasible, non-invasive, and simple tool easily applicable in daily practice. An increase of >2°C showed a high-sensitivity and specificity for the diagnosis of late-onset sepsis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura Corporal / Sepse / Doenças do Prematuro Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Newborn Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura Corporal / Sepse / Doenças do Prematuro Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Newborn Idioma: En Ano de publicação: 2012 Tipo de documento: Article