Your browser doesn't support javascript.
loading
Two-year radiologic assessment of the Trident Peripheral Self-Locking cup using EBRA.
Nunag, Perrico; Deakin, Angela H; Oburu, Ezekiel; Sarungi, Martin.
Afiliação
  • Nunag P; Department of Orthopaedics, Golden Jubilee National Hospital, Agamemnon Street, Clydebank, Dunbartonshire, UK.
Hip Int ; 22(5): 511-5, 2012.
Article em En | MEDLINE | ID: mdl-23100151
ABSTRACT
UNLABELLED We performed a radiologic assessment of the Trident Peripheral Self-Locking cup 2 years after implantation to assess early migration behaviour and to establish if incomplete postoperative seating correlated with early instability. A retrospective analysis of 30 cases was performed using EBRA. No cups had acetabular screws. Average total migration was 1.5 mm (range 0.1 to 5.9 mm). Seventeen showed total migration >1 mm and 7 of these showed further migration >2 mm (range 2.3 to 5.9 mm). Twenty cups demonstrated incomplete seating on initial post-operative radiographs (mean 1.4 mm, range 0.3 to 3.0). No relationship between incomplete seating and migration was identified (p = 0.86). The majority of gaps consolidated at differing times within the 2 year period. Oxford Hip scores showed significant improvement after surgery (p = 0.001) and this was independent of migration (p = 0.76). At 5 years there were no revisions for aseptic loosening.

CONCLUSION:

The majority of the cups demonstrated early radiographic instability, and this was not related to incomplete seating. Five year functional outcome appears good and independent of migration and initial seating.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Análise de Falha de Equipamento / Artroplastia de Quadril / Articulação do Quadril / Prótese de Quadril / Instabilidade Articular Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Análise de Falha de Equipamento / Artroplastia de Quadril / Articulação do Quadril / Prótese de Quadril / Instabilidade Articular Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article