Your browser doesn't support javascript.
loading
Comparison of the diagnostic performance of three natriuretic peptides in hemodialysis patients: which is the appropriate biomarker?.
Artunc, Ferruh; Mueller, Christian; Breidthardt, Tobias; Twerenbold, Raphael; Rettig, Ingo; Usta, Engin; Häring, Hans-Ulrich; Friedrich, Björn.
Afiliação
  • Artunc F; Department of Internal Medicine, Division of Endocrinology, Diabetology, Vascular Disease, Nephrology and Clinical Chemistry, University of Tübingen, Germany. ferruh.artunc@med.uni-tuebingen.de
Kidney Blood Press Res ; 36(1): 172-81, 2012.
Article em En | MEDLINE | ID: mdl-23108497
ABSTRACT

BACKGROUND:

Plasma concentrations of natriuretic peptides are often elevated in chronic hemodialysis patients and difficult to interpret due to accumulation, high incidence of cardiac disease and changes in volume status. Mid-regional pro-ANP is a newly developed assay whereas BNP and its fragment NT-pro-BNP are available for a longer time. In this cross-sectional study, we compared the plasma concentration of MR-pro-ANP, BNP and NT-pro-BNP in stable ambulatory hemodialysis patients (n = 239) and investigated their associations with clinical factors such as residual diuresis, cardiac status and interdialytic weight gain and with mortality. METHODS AND

RESULTS:

In all patients enrolled, the plasma concentration of all natriuretic peptides were largely elevated with a median concentration of 337 pg/ml (interquartile range 146-684) for BNP, 4435 pg/ml (1687-16228) for NT-proBNP and 907 pmol/L (650-1298) for MR-pro-ANP. Plasma concentration of all natriuretic peptides correlated independently with age, degree of systolic dysfunction and negatively with residual diuresis. Dependency on residual renal clearance was strongest for the fragments MR-pro-ANP and NT-pro-BNP. The plasma concentration of all natriuretic peptides was associated with mortality within 2 years of follow-up. Receiver-operated curves revealed a low sensitivity (32-45%), but high specificity for all natriuretic peptides (85-93%) resulting in a high negative predictive (82-87%). Best cut-off values obtained from were 18 611 pg/ml for NT-pro-BNP, 958 pg/ml for BNP and 1684 pmol/L for MR-pro-ANP.

CONCLUSIONS:

In hemodialysis patients, the fragments NTproBNP and MR-pro-ANP are largely elevated compared to BNP which is explained by accumulation. The prognostic performance of MR-pro-ANP is similar to that of NT-pro-BNP or BNP.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Diálise Renal / Fator Natriurético Atrial / Peptídeo Natriurético Encefálico / Falência Renal Crônica Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Diálise Renal / Fator Natriurético Atrial / Peptídeo Natriurético Encefálico / Falência Renal Crônica Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article