Your browser doesn't support javascript.
loading
Prioritizing echocardiography in Staphylococcus aureus bacteraemia.
Joseph, Jubin P; Meddows, Tom R; Webster, Daniel P; Newton, James D; Myerson, Saul G; Prendergast, Bernard; Scarborough, Matthew; Herring, Neil.
Afiliação
  • Joseph JP; Oxford Heart Centre, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford OX3 9DU, UK.
J Antimicrob Chemother ; 68(2): 444-9, 2013 Feb.
Article em En | MEDLINE | ID: mdl-23111851
ABSTRACT

OBJECTIVES:

Infective endocarditis (IE) is a severe complication in Staphylococcus aureus bacteraemia (SAB) and recent guidelines from the BSAC recommend all patients undergo echocardiography. We assessed the use of echocardiography at a major tertiary referral centre and sought to identify those patients most likely to have positive findings.

METHODS:

We retrospectively evaluated all cases of SAB at Oxford University Hospitals NHS Trust between September 2006 and August 2011.

RESULTS:

Three-hundred-and-six out of 668 patients with SAB underwent cardiac imaging on average 9.8 ± 1.3 days from the first culture. Thirty-one patients (10.1%) had echocardiographic evidence of IE. Risk factors for observing evidence of IE on scanning included the presence of prosthetic heart valves (32% versus 4%, P < 0.001) or cardiac rhythm management (CRM) devices (16% versus 3%, P < 0.004). On excluding patients with prosthetic valves or CRM devices from the analysis, no patient with a line-related bacteraemia and only one patient (an intravenous drug user) with no/mild regurgitation on transthoracic echocardiography had echo evidence of IE.

CONCLUSIONS:

We propose that the use of scarce echocardiography resources could be prioritized. Patients with prosthetic heart valves or a CRM device should receive early cardiological input and transoesophageal echocardiography. In patients with a clearly defined line-related bacteraemia who do not have a prosthetic valve or CRM device or clinical features of IE, response to treatment could be closely monitored and imaging deferred. Patients without a line-related infection or prosthetic valve/device could receive a transthoracic echocardiogram as a screening tool.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Bacteriemia / Ecocardiografia Transesofagiana / Endocardite Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Bacteriemia / Ecocardiografia Transesofagiana / Endocardite Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article