ABSTRACT
STATEMENT OF

PROBLEM:

Fracture of feldspathic porcelain laminate veneers represents a significant mode of clinical failure. Therefore, ceramic materials that withstand a higher load to fracture, especially for patients with parafunctional habits, are needed.

PURPOSE:

The purpose of this study was to examine the correlation of material (zirconia, TZP, glass-ceramic, IEC, and feldspathic porcelain, FP) design (incisal overlapped preparation, IOP, and three-quarter preparation, TQP), and fracture mode to failure load for veneers supported by composite resin abutments. MATERIAL AND

METHODS:

A typodont tooth prepared with 2 designs (IOP, TQP) and the corresponding 2 definitive dies were used to fabricate the composite resin abutments (30 for IOP and 30 for TQP). Ten veneer specimens for each system (Y-TZP, IEC, and FP), were fabricated for each design. The veneers were cemented, invested, and tested in compression until failure by using a universal testing machine. Significant differences were evaluated by 2-factor ANOVA (α=.05).

RESULTS:

No statistical mean load difference was noted between the preparation designs for Y-TZP (IOP 244 ±81 and TQP 224 ±58 N), IEC (IOP 306 ±101 and TQP 263 ±77 N), and FP veneers (IOP 161 ±93 and TQP 246 ±45 N). No statistical difference in the mean load was found among the 3 veneer materials for each preparation design except between IEC (306 ±101 N) and FP (161 ±93 N) veneers for TQP.

CONCLUSIONS:

Preparation design did not influence the failure load of the veneer materials. Zirconia veneers were the least likely to fracture but the most likely to completely debond; feldspathic porcelain veneers exhibited the opposite characteristics.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ítrio / Zircônio / Cerâmica / Planejamento de Prótese Dentária / Desenho Assistido por Computador / Porcelana Dentária / Facetas Dentárias Limite: Humans Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ítrio / Zircônio / Cerâmica / Planejamento de Prótese Dentária / Desenho Assistido por Computador / Porcelana Dentária / Facetas Dentárias Limite: Humans Idioma: En Ano de publicação: 2012 Tipo de documento: Article