Your browser doesn't support javascript.
loading
Poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liner in primary total hip replacement: one-year results of a prospective cohort study.
Takatori, Yoshio; Moro, Toru; Kamogawa, Morihide; Oda, Hiromi; Morimoto, Shuhei; Umeyama, Takashige; Minami, Manabu; Sugimoto, Hideharu; Nakamura, Shigeru; Karita, Tatsuro; Kim, Juntaku; Koyama, Yurie; Ito, Hideya; Kawaguchi, Hiroshi; Nakamura, Kozo.
Afiliação
  • Takatori Y; Division of Science for Joint Reconstruction, The University of Tokyo, Tokyo, Japan. takatori-ort@h.u-tokyo.ac.jp
J Artif Organs ; 16(2): 170-5, 2013 Jun.
Article em En | MEDLINE | ID: mdl-23238557
ABSTRACT
To control particle-induced osteolysis in total hip replacement (THR), we developed a new technique to graft poly(2-methacryloyloxyethyl phosphorylcholine) onto the surface of polyethylene liners. A prospective cohort study was conducted to investigate the clinical safety of this novel bearing surface. Between April 2007 and September 2008, we recruited a prospective consecutive series of 80 patients in five participating hospitals. These patients received a cementless THR; a 26-mm-diameter cobalt-chromium-molybdenum alloy ball and a poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liner were used for the bearing couplings. These individuals were followed a year postoperatively. An evaluation of clinical performance was conducted through an assessment of hip joint function based on the evaluation chart authorized by the Japanese Orthopaedic Association. No patients were lost to follow-up. No adverse events were found to be correlated with the implanted liners. The average hip joint function score improved from 43.2 preoperatively to 91.7 postoperatively at 1 year. There was no implant migration nor periprosthetic osteolysis detected on radiographic analysis. On the basis of our results, we conclude that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liners are a safe implant option for hip replacement surgery for short-term clinical use.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosforilcolina / Artroplastia de Quadril / Prótese de Quadril / Metacrilatos Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosforilcolina / Artroplastia de Quadril / Prótese de Quadril / Metacrilatos Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article