BACKGROUND:
We previously described the feasibility of myocardial perfusion imaging (MPI) with nearly half the radiation dose using ordered-subset expectation maximization with resolution recovery (OSEM-RR) processing. This study sought to determine if the findings can be expanded to obese patients.METHODS:
Fifty obese patients (>100 kg) referred for MPI underwent stress-rest or rest-stress studies with a half dose of Tc-99m sestamibi in a 1-day protocol using OSEM-RR processing. Image quality and clinical results were compared with matched patients (by age, sex, weight, presence/probability of coronary artery disease) evaluated with standard "full-dose" Tc-99m sestamibi, mostly in a 2-day protocol. Dose activities were adjusted individually by weight.RESULTS:
Mean Tc-99m activity was 33.4 ± 13.9 mCi in the half-dose group and 60 ± 10 mCi in the full-dose group (P < .0001). Respective mean effective doses per study were 10 ± 4 and 18 ± 3 mSv (P < .0001). Overall image quality was good-to-excellent in 94% of the half-dose group and 80% of the full-dose group (P < .045). There was no between-group difference in rate or size of ischemia or infarction, except for stress left ventricular ejection fraction.CONCLUSIONS:
MPI with half the radiation dose is feasible in obese patients. Image quality is better than for full-dose MPI, and the procedure can be performed in 1 day.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Doença da Artéria Coronariana
/
Processamento de Imagem Assistida por Computador
/
Imagem de Perfusão do Miocárdio
/
Obesidade
Tipo de estudo:
Diagnostic_studies
/
Guideline
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2013
Tipo de documento:
Article