Your browser doesn't support javascript.
loading
Glenoid bone loss: assessment with MR imaging.
Lee, Ryan K L; Griffith, James F; Tong, Mabel M P; Sharma, Nimish; Yung, Patrick.
Afiliação
  • Lee RK; Department of Imaging and Interventional Radiology and Department of Orthopedics and Traumatology, the Chinese University of Hong Kong, Prince of Wales Hospital, 30-32 Ngan Shing St, Shatin, NT, Hong Kong SAR, China. leekalok2909@yahoo.com.hk
Radiology ; 267(2): 496-502, 2013 May.
Article em En | MEDLINE | ID: mdl-23329661
ABSTRACT

PURPOSE:

To investigate the agreement among magnetic resonance (MR) imaging, computed tomography (CT), and arthroscopy in the measurement of glenoid bone loss. MATERIALS AND

METHODS:

This study was approved by the institutional ethics committee. One hundred seventy-six patients (158 male and 18 female patients; mean age, 26.8 years ± 12.3) with anterior shoulder dislocation underwent both shoulder MR imaging and CT examination. Anterior straight line length, glenoid width, and best-fit bone loss were measured with MR imaging and CT. Sixty-five patients also underwent arthroscopy, which was used as the standard of reference. Assessment of glenoid bone loss at MR imaging was compared with that at CT and arthroscopy. Inter- and intrareader reproducibility of MR imaging-derived measurements of glenoid bone loss was evaluated.

RESULTS:

There was excellent correlation between CT and MR imaging with regard to anterior straight line length (r = 0.97, P < .0001), glenoid width (r = 0.95, P < .0001), and severity of glenoid bone loss-particularly with use of best-fit circle width (r = 0.83, P < .0001) rather than best-fit circle area (r = 0.82, P < .0001). In the assessment of glenoid bone loss, the correlation between CT and arthroscopy (r = 0.91, P < .0001) was marginally better than that between MR imaging and arthroscopy (r = 0.84, P < .0001). The inter- and intrareader correlations of MR imaging-derived measurements of glenoid bone loss were excellent (R = 0.90-0.95).

CONCLUSION:

MR imaging assessment of glenoid bone loss, particularly with use of glenoid width, is almost as accurate as CT assessment.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escápula / Luxação do Ombro / Articulação do Ombro / Reabsorção Óssea / Imageamento por Ressonância Magnética Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escápula / Luxação do Ombro / Articulação do Ombro / Reabsorção Óssea / Imageamento por Ressonância Magnética Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article