Rapid inspection method for measuring interior tilt and decenter in singlet lens.
Chang, Ching-Yuan; Ma, Chien-Ching; Huang, Kuo-Cheng; Tseng, Shih-Feng.
Afiliação
  • Chang CY; Mechanical Engineering Department, National Taiwan University, Taipei, Taiwan.
Appl Opt ; 52(4): B70-81, 2013 Feb 01.
Article em En | MEDLINE | ID: mdl-23385944
ABSTRACT
The objective of this study was to present a high-speed, on-line means of measuring interior tilt and decentration in a singlet lens. We propose a noncontact method based on polarized optics, which provides inspection functions for the practical measurement of lenses. The proposed system was used to measure a tilted and decentered lens, and the results of which showed strong agreement with those obtained in theoretical predictions and CodeV simulations. The proposed method provides a wide field of inspection applicable to lenses with a diameter up to 70 mm. Measurement accuracy is of 0.14 deg/pixel in tilt, and 33 µm/pixel in decentration. Inspection time is only 0.78 s.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2013 Tipo de documento: Article