Your browser doesn't support javascript.
loading
Catheter ablation of atrial fibrillation guided by a 3D electroanatomical mapping system: a 2-year follow-up study from the Italian Registry On NavX Atrial Fibrillation ablation procedures (IRON-AF).
Forleo, Giovanni B; De Martino, Giuseppe; Mantica, Massimo; Menardi, Endrj; Trevisi, Nicola; Faustino, Massimiliano; Muto, Carmine; Perna, Francesco; Santamaria, Matteo; Pandozi, Claudio; Pappalardo, Augusto; Mancusi, Carmine; Romano, Enrico; Della Bella, Paolo; Tondo, Claudio.
Afiliação
  • Forleo GB; Division of Cardiology, Policlinico Universitario Tor Vergata, Viale Oxford, 81, 00133, Rome, Italy. forleo@me.com
J Interv Card Electrophysiol ; 37(1): 87-95, 2013 Jun.
Article em En | MEDLINE | ID: mdl-23397247
ABSTRACT

AIMS:

Clinical trials have established that atrial fibrillation (AF) catheter ablation improves symptoms in appropriately selected patients. Confirmation of these results by long-term prospective observational studies is needed. This registry was created to describe the experience of 16 Italian centers with a large cohort of AF patients treated with catheter ablation guided by the NavX 3D mapping system.

METHODS:

From November 2006 to May 2008, 545 consecutive patients (age 60.4 ± 9.8, 67 % male) with paroxysmal (44 %), persistent (43 %), and long-standing persistent (13 %) AF referred for catheter ablation guided by the NavX system, were included in this registry. For this paper, follow-up was censored at 24 months; however, patients are being followed in the ongoing registry.

RESULTS:

Before the ablation, 80 % of patients failed to respond to at least one antiarrhythmic drug aimed at rhythm control. Pulmonary vein (PV) isolation guided by a circular mapping catheter was performed in 70 % of patients whereas non potential-guided PV encircling was performed in 30 % of patients. In 67 % of patients, additional left atrial (LA) substrate modification was performed. Image integration was performed in 9.2 % of patients. Considering a 3-month blanking period, after a single-ablation procedure, the patients had 1- and 2-year freedom from AF recurrence of 67.4 and 57.0 % (36.1 % off antiarrhythmic drugs), respectively. Cox regression analysis showed that AF recurrences during blanking (HR 2.1), and previous AF ablation (HR 3.3) were independent predictors of AF recurrences. Major procedure-related complications occurred in 53 patients (9.7 %). In 35 patients (6.7 %), a repeat procedure was performed at a median of 5 months after the initial procedure.

CONCLUSIONS:

This prospective, multicenter clinical experience provides significant insights into current ablation care of patients with AF. Despite favorable outcomes, real-world complication rates appear higher than previously recognized.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Sistema de Registros / Ablação por Cateter / Mapeamento Potencial de Superfície Corporal / Imageamento Tridimensional / Cirurgia Assistida por Computador Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Sistema de Registros / Ablação por Cateter / Mapeamento Potencial de Superfície Corporal / Imageamento Tridimensional / Cirurgia Assistida por Computador Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article