Is SAPS 3 better than APACHE II at predicting mortality in critically ill transplant patients?
Oliveira, Vanessa M de; Brauner, Janete S; Rodrigues Filho, Edison; Susin, Ruth G A; Draghetti, Viviane; Bolzan, Simone T; Vieira, Silvia R R.
Afiliação
  • Oliveira VM; Intensive Care Unit, Hospital de Clínicas de Porto Alegre, Porto Alegre, RS, Brazil. vannessm@bol.com.br
Clinics (Sao Paulo) ; 68(2): 153-8, 2013.
Article em En | MEDLINE | ID: mdl-23525309
OBJECTIVES: This study compared the accuracy of the Simplified Acute Physiology Score 3 with that of Acute Physiology and Chronic Health Evaluation II at predicting hospital mortality in patients from a transplant intensive care unit. METHOD: A total of 501 patients were enrolled in the study (152 liver transplants, 271 kidney transplants, 54 lung transplants, 24 kidney-pancreas transplants) between May 2006 and January 2007. The Simplified Acute Physiology Score 3 was calculated using the global equation (customized for South America) and the Acute Physiology and Chronic Health Evaluation II score; the scores were calculated within 24 hours of admission. A receiver-operating characteristic curve was generated, and the area under the receiver-operating characteristic curve was calculated to identify the patients at the greatest risk of death according to Simplified Acute Physiology Score 3 and Acute Physiology and Chronic Health Evaluation II scores. The Hosmer-Lemeshow goodness-of-fit test was used for statistically significant results and indicated a difference in performance over deciles. The standardized mortality ratio was used to estimate the overall model performance. RESULTS: The ability of both scores to predict hospital mortality was poor in the liver and renal transplant groups and average in the lung transplant group (area under the receiver-operating characteristic curve = 0.696 for Simplified Acute Physiology Score 3 and 0.670 for Acute Physiology and Chronic Health Evaluation II). The calibration of both scores was poor, even after customizing the Simplified Acute Physiology Score 3 score for South America. CONCLUSIONS: The low predictive accuracy of the Simplified Acute Physiology Score 3 and Acute Physiology and Chronic Health Evaluation II scores does not warrant the use of these scores in critically ill transplant patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Indicadores Básicos de Saúde / Transplante de Rim / Transplante de Fígado / Transplante de Pulmão / Transplante de Pâncreas / Mortalidade Hospitalar Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: America do sul / Brasil Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Indicadores Básicos de Saúde / Transplante de Rim / Transplante de Fígado / Transplante de Pulmão / Transplante de Pâncreas / Mortalidade Hospitalar Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: America do sul / Brasil Idioma: En Ano de publicação: 2013 Tipo de documento: Article