Your browser doesn't support javascript.
loading
Radiation dose in defecography.
Goei, R; Kemerink, G.
Afiliação
  • Goei R; Department of Radiology, University Hospital Maastricht, University of Limburg, The Netherlands.
Radiology ; 176(1): 137-9, 1990 Jul.
Article em En | MEDLINE | ID: mdl-2353082
The effective dose equivalent, as an expression of total patient risk for exposure to limited areas of the body, and gonadal doses associated with hereditary effects were estimated in 67 consecutive subjects (43 women and 24 men) who underwent defecography. With use of measured entrance exposure values and data from Monte Carlo simulations, the mean effective dose equivalent was estimated at 4.9 mSv +/- 1.6 (490 mrem +/- 160) for women and 0.6 mSv +/- 0.2 (60 mrem +/- 20) for men. The ovarian dose was 15 mSv +/- 5 (1.5 rem +/- 0.5). The testes are not within the primary beam and therefore are exposed to scattered radiation only, hence the low received dose of 0.14 mSv or less (14 mrem or less). These data indicate that defecography is among the radiologic procedures associated with a considerable, but not extreme, radiation dose.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Defecação / Enteropatias Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1990 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Defecação / Enteropatias Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1990 Tipo de documento: Article