Your browser doesn't support javascript.
loading
Feasibility of image-based simulation to estimate ablation target in human ventricular arrhythmia.
Ashikaga, Hiroshi; Arevalo, Hermenegild; Vadakkumpadan, Fijoy; Blake, Robert C; Bayer, Jason D; Nazarian, Saman; Muz Zviman, M; Tandri, Harikrishna; Berger, Ronald D; Calkins, Hugh; Herzka, Daniel A; Trayanova, Natalia A; Halperin, Henry R.
Afiliação
  • Ashikaga H; Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, USA. hashika1@jhmi.edu
Heart Rhythm ; 10(8): 1109-16, 2013 Aug.
Article em En | MEDLINE | ID: mdl-23608593
ABSTRACT

BACKGROUND:

Previous studies suggest that magnetic resonance imaging with late gadolinium enhancement (LGE) may identify slowly conducting tissues in scar-related ventricular tachycardia (VT).

OBJECTIVE:

To test the feasibility of image-based simulation based on LGE to estimate ablation targets in VT.

METHODS:

We conducted a retrospective study in 13 patients who had preablation magnetic resonance imaging for scar-related VT ablation. We used image-based simulation to induce VT and estimate target regions according to the simulated VT circuit. The estimated target regions were coregistered with the LGE scar map and the ablation sites from the electroanatomical map in the standard ablation approach.

RESULTS:

In image-based simulation, VT was inducible in 12 (92.3%) patients. All VTs showed macroreentrant propagation patterns, and the narrowest width of estimated target region that an ablation line should span to prevent VT recurrence was 5.0 ± 3.4 mm. Of 11 patients who underwent ablation, the results of image-based simulation and the standard approach were consistent in 9 (82%) patients, where ablation within the estimated target region was associated with acute success (n = 8) and ablation outside the estimated target region was associated with failure (n = 1). In 1 (9%) case, the results of image-based simulation and the standard approach were inconsistent, where ablation outside the estimated target region was associated with acute success.

CONCLUSIONS:

The image-based simulation can be used to estimate potential ablation targets of scar-related VT. The image-based simulation may be a powerful noninvasive tool for preprocedural planning of ablation procedures to potentially reduce the procedure time and complication rates.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cicatriz / Taquicardia Ventricular / Ablação por Cateter / Gadolínio / Ventrículos do Coração Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cicatriz / Taquicardia Ventricular / Ablação por Cateter / Gadolínio / Ventrículos do Coração Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article