Effect of aortic valve movements on gastrointestinal bleeding that occured in continuous flow left ventricular assist device patients.
Transplant Proc
; 45(3): 1020-1, 2013 Apr.
Article
em En
| MEDLINE
| ID: mdl-23622613
BACKGROUND: Gastrointestinal (GI) bleeding is one of the recently reported complications with continuous flow left ventricular assist devices (LVAD). The pathophysiology and etiology are unclear. We sought to describe the relationship between aortic valve movements and GI bleeding among patients with a new generation of LVAD. METHODS: We evaluated the data of 30 patients who underwent LVAD (HeartWare VAD) implantation from December 2010 to September 2012. The most common etiologic diagnosis was dilated cardiomyopathy. Patients were considered to show GI bleeding if they had hematemesis, melena, or hematochezia. RESULTS: Among 3 patients, 2 displayed upper GI bleeding and 1 had lower GI bleeding based on endoscopic and colononoscopic examinations. Pathological reports showed arteriovenous malformations in patients diagnosed with upper GI bleeding. The absence of aortic valve movements and a history of previous GI bleeding were significant risk factors (P = .021 and P = .007, respectively). CONCLUSION: In addition to aortic valve movements, we believe that a GI bleeding history was an equally important factor predisposing to this complication.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Valva Aórtica
/
Coração Auxiliar
/
Hemorragia Gastrointestinal
Tipo de estudo:
Etiology_studies
/
Risk_factors_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2013
Tipo de documento:
Article