Your browser doesn't support javascript.
loading
Intra- and interscan reproducibility using Fourier Analysis of STimulated Echoes (FAST) for the rapid and robust quantification of left ventricular twist.
Reyhan, Meral; Kim, Hyun J; Brown, Matthew S; Ennis, Daniel B.
Afiliação
  • Reyhan M; Biomedical Physics Interdepartmental Program University of California, Los Angeles, California, USA; Department of Radiological Sciences, University of California, Los Angeles, California, USA.
J Magn Reson Imaging ; 39(2): 463-8, 2014 Feb.
Article em En | MEDLINE | ID: mdl-23633244
PURPOSE: To assess the intra- and interscan reproducibility of LV twist using FAST. Assessing the reproducibility of the measurement of new MRI biomarkers is an important part of validation. Fourier Analysis of STimulated Echoes (FAST) is a new MRI tissue tagging method that has recently been shown to compare favorably with conventional estimates of left ventricular (LV) twist from cardiac tagged images, but with significantly reduced user interaction time. MATERIALS AND METHODS: Healthy volunteers (N = 10) were scanned twice using FAST over 1 week. On day 1, two measurements of LV twist were collected for intrascan comparisons. Measurements for LV twist were again collected on day 8 for interscan assessment. LV short-axis tagged images were acquired on a 3 Tesla (T) scanner to ensure detectability of tags during early and mid-diastole. Peak LV twist is reported as mean ± SD. Reproducibility was assessed using the concordance correlation coefficient (CCC) and the repeatability coefficient (RC) (95% confidence interval [CI] range). RESULTS: Mean peak twist measurements were 13.4 ± 4.3° (day 1, scan 1), 13.6 ± 3.7° (day 1, scan 2), and 13.0 ± 2.7° (day 8). Bland-Altman analysis resulted in intra- and interscan bias and 95% CI of -0.6° [-1.0°, 1.6°] and 1.4° (-1.0°, 3.0°), respectively. The Bland-Altman RC for peak LV twist was 2.6° and 4.0° for intra- and interscan, respectively. The CCC was 0.9 and 0.6 for peak LV twist for intra- and interscan, respectively. CONCLUSION: FAST is a semi-automated method that provides a quick and quantitative assessment of LV systolic and diastolic twist that demonstrates high intrascan and moderate interscan reproducibility in preliminary studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Anormalidade Torcional / Reconhecimento Automatizado de Padrão / Interpretação de Imagem Assistida por Computador / Disfunção Ventricular Esquerda / Imagem Cinética por Ressonância Magnética / Imageamento Tridimensional / Ventrículos do Coração Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Anormalidade Torcional / Reconhecimento Automatizado de Padrão / Interpretação de Imagem Assistida por Computador / Disfunção Ventricular Esquerda / Imagem Cinética por Ressonância Magnética / Imageamento Tridimensional / Ventrículos do Coração Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2014 Tipo de documento: Article