Your browser doesn't support javascript.
loading
Use of rapid HIV assays as supplemental tests in specimens with repeatedly reactive screening immunoassay results not confirmed by HIV-1 Western blot.
Wesolowski, Laura G; Delaney, Kevin P; Meyer, William A; Blatt, Amy J; Bennett, Berry; Chavez, Pollyanna; Granade, Timothy C; Owen, Michele.
Afiliação
  • Wesolowski LG; Division of HIV/AIDS Prevention, National Center for HIV, Hepatitis, STD & TB Prevention, Centers for Disease Control and Prevention (CDC), 1600 Clifton Road, MS-E46, Atlanta, GA 30333, USA. lig7@cdc.gov
J Clin Virol ; 58(1): 240-4, 2013 Sep.
Article em En | MEDLINE | ID: mdl-23838670
ABSTRACT

BACKGROUND:

An alternate HIV testing algorithm has been proposed which includes a fourth-generation immunoassay followed by an HIV-1/HIV-2 antibody differentiation supplemental test for reactive specimens and a nucleic acid test (NAT) for specimens with discordant results.

OBJECTIVE:

To evaluate the performance of five rapid tests (Alere Clearview, Bio-Rad Multispot, OraSure OraQuick, MedMira Reveal, and Trinity Biotech Unigold) as the supplemental antibody assay in the algorithm. STUDY

DESIGN:

A total of 3273 serum and plasma specimens that were third-generation immunoassay repeatedly reactive and Western blot (WB) negative or indeterminate were tested with rapid tests and NAT. Specimens were classified by NAT (1) HIV-1 infected (NAT-reactive; n=184, 5.6%), (2) HIV-status unknown (NAT nonreactive; n=3078, 94.2%) or by Multispot, (3) HIV-2 positive (n=5), and (4) HIV-1 and HIV-2 positive (n=6). Excluding HIV-2 positive specimens, we calculated the proportion of reactive rapid tests among specimens with reactive and nonreactive NAT.

RESULTS:

The proportion of infected specimens with reactive rapid test results and negative or indeterminate WB ranged from 30.4% (56) to 47.8% (88) depending on the rapid test. From 1% to 2% of NAT-negative specimens had reactive rapid test results.

CONCLUSIONS:

In these diagnostically challenging specimens, all rapid tests identified infections that were missed by the Western blot, but only Multispot could differentiate HIV-1 from HIV-2. Regardless of which rapid test is used as a supplemental test in the alternative algorithm, false-positive algorithm results (i.e., reactive screening and rapid test in uninfected person) may occur, which will need to be resolved during the baseline medical evaluation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por HIV / HIV-1 / HIV-2 / Sistemas Automatizados de Assistência Junto ao Leito / Técnicas de Laboratório Clínico Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por HIV / HIV-1 / HIV-2 / Sistemas Automatizados de Assistência Junto ao Leito / Técnicas de Laboratório Clínico Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2013 Tipo de documento: Article