Your browser doesn't support javascript.
loading
Simulating the effect of interaural mismatch in the insertion depth of bilateral cochlear implants on speech perception.
van Besouw, Rachel M; Forrester, Lisa; Crowe, Nicholas D; Rowan, Daniel.
Afiliação
  • van Besouw RM; Institute of Sound and Vibration Research, University of Southampton, Southampton, Hampshire, SO17 1BJ, United Kingdom. rvb@isvr.soton.ac.uk
J Acoust Soc Am ; 134(2): 1348-57, 2013 Aug.
Article em En | MEDLINE | ID: mdl-23927131
ABSTRACT
A bilateral advantage for diotically presented stimuli has been observed for cochlear implant (CI) users and is suggested to be dependent on symmetrical implant performance. Studies using CI simulations have not shown a true "bilateral" advantage, but a "better ear" effect and have demonstrated that performance decreases with increasing basalward shift in insertion depth. This study aimed to determine whether there is a bilateral advantage for CI simulations with interaurally matched insertions and the extent to which performance is affected by interaural insertion depth mismatch. Speech perception in noise and self-reported ease of listening were measured using matched bilateral, mismatched bilateral and unilateral CI simulations over four insertion depths for seventeen normal hearing listeners. Speech scores and ease of listening reduced with increasing basalward shift in (interaurally matched) insertion depth. A bilateral advantage for speech perception was only observed when the insertion depths were interaurally matched and deep. No advantage was observed for small to moderate interaural insertion-depth mismatches, consistent with a better ear effect. Finally, both measures were poorer than expected for a better ear effect for large mismatches, suggesting that misalignment of the electrode arrays may prevent a bilateral advantage and detrimentally affect perception of diotically presented speech.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Correção de Deficiência Auditiva / Percepção da Fala / Implantes Cocleares / Ajuste de Prótese / Pessoas com Deficiência Auditiva / Implante Coclear Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Correção de Deficiência Auditiva / Percepção da Fala / Implantes Cocleares / Ajuste de Prótese / Pessoas com Deficiência Auditiva / Implante Coclear Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2013 Tipo de documento: Article