Arterial closure devices for treatment of inadvertent large-caliber catheter insertion into the subclavian or carotid artery: a case series of five patients.
Stellmes, Arno; Diehm, Nicolas; Book, Malte; Schmidli, Jürg; Do, Dai-Do; Gralla, Jan.
Afiliação
  • Stellmes A; Department of Cardiovascular Surgery, University Hospital Berne, Berne, Switzerland.
  • Diehm N; Department of Angiology, University Hospital Berne, Berne, Switzerland. Electronic address: nicolas.diehm@insel.ch.
  • Book M; Department of Anaesthesiology, University Hospital Berne, Berne, Switzerland.
  • Schmidli J; Department of Cardiovascular Surgery, University Hospital Berne, Berne, Switzerland.
  • Do DD; Department of Angiology, University Hospital Berne, Berne, Switzerland.
  • Gralla J; Department of Neuroradiology, University Hospital Berne, Berne, Switzerland.
J Cardiothorac Vasc Anesth ; 28(5): 1319-22, 2014 Oct.
Article em En | MEDLINE | ID: mdl-24016686

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Subclávia / Cateterismo Venoso Central / Artéria Carótida Primitiva / Erros Médicos / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Subclávia / Cateterismo Venoso Central / Artéria Carótida Primitiva / Erros Médicos / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article