Your browser doesn't support javascript.
loading
A comparison of methods for EGFR mutation testing in non-small cell lung cancer.
Young, Elizabeth C; Owens, Martina M; Adebiyi, Idowu; Bedenham, Tina; Butler, Rachel; Callaway, Jonathan; Cranston, Treena; Crosby, Charlene; Cree, Ian A; Dutton, Laura; Faulkes, Catherine; Faulkner, Claire; Howard, Emma; Knight, Julia; Huang, Yuanxue; Lavender, Louise; Lazarou, Lazarus P; Liu, Hongxiang; Mair, Debbie; Milano, Antonio; Sandell, Stacey; Skinner, Alison; Wallace, Andrew; Williams, Maggie; Spivey, Vicky; Goodall, John; Frampton, Jonathan; Ellard, Sian.
Afiliação
  • Young EC; *Molecular Genetics Department, Royal Devon and Exeter NHS Trust, Exeter †Molecular Genetics, Institute of Medical Genetics, Cardiff and Vale NHS Trust, Cardiff, Wales ‡Oxford Medical Genetics Laboratories, Oxford University Hospitals NHS Trust, Oxford §Wessex Regional Genetics Laboratory, Salisbury Health Care NHS Trust, Wiltshire ∥Bristol Genetics Laboratory, Southmead Hospital, Bristol ¶Department of Pathology, Warwick Medical School, University Hospitals Coventry and Warwickshire, Coventry #
Diagn Mol Pathol ; 22(4): 190-5, 2013 Dec.
Article em En | MEDLINE | ID: mdl-24193010
ABSTRACT
EGFR mutation testing of tumor samples is routinely performed to predict sensitivity to treatment with tyrosine kinase inhibitors for patients with non-small cell lung cancer. At least 9 different methodologies are employed in UK laboratories, and the aim of this study was to compare the sensitivity of different methods for the detection of EGFR mutations. Participating laboratories were sent coded samples with varying mutation loads (from 0% to 15%) to be tested for the p.Leu858Arg (p.L858R) missense mutation and c.2235_2249del exon 19 deletion. The p.L858R mutation and deletions within exon 19 of the EGFR gene account for ∼90% of mutation-positive cases. The 11 laboratories used their standard testing method(s) and submitted 15 sets of results for the p.L858R samples and 10 for the exon 19 deletion. The p.Leu858Arg (p.L858R) mutation was detected at levels between 1% and 7.5% by Sanger sequencing, pyrosequencing, real-time polymerase chain reaction (PCR), amplification refractory mutation system, and capillary electrophoresis single-strand conformation analysis. The c.2235_2249del mutation was detected at 1% to 5% by fragment size analysis, Sanger sequencing or real-time PCR. A mutation was detected in 24/25 (96%) of the samples tested which contained 5% mutated DNA. The 1% sensitivity claimed for commercial real-time PCR-targeted EGFR tests was achieved and our results show greater sensitivity for the Sanger sequencing and pyrosequencing screening methods compared to the 10% to 20% detection levels cited on clinical diagnostic reports. We conclude that multiple methodologies are suitable for the detection of acquired EGFR mutations.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Deleção de Sequência / Carcinoma Pulmonar de Células não Pequenas / Mutação de Sentido Incorreto / Patologia Molecular / Receptores ErbB Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Deleção de Sequência / Carcinoma Pulmonar de Células não Pequenas / Mutação de Sentido Incorreto / Patologia Molecular / Receptores ErbB Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article