Intraobserver and interobserver variability in computed tomography size and attenuation measurements in patients with renal cell carcinoma receiving antiangiogenic therapy: implications for alternative response criteria.
Cancer
; 120(5): 711-21, 2014 Mar 01.
Article
em En
| MEDLINE
| ID: mdl-24264883
BACKGROUND: Alternative response criteria have been proposed in patients with metastatic renal cell carcinoma (mRCC) who are receiving vascular endothelial growth factor (VEGF)-targeted therapy, including 10% tumor shrinkage as an indicator of response/outcome. However, to the authors' knowledge, intraobserver and interobserver measurement variability have not been defined in this setting. The objective of the current study was to determine intraobserver and interobserver agreement of computed tomography (CT) size and attenuation measurements to establish reproducible response indicators. METHODS: Seventy-one patients with mRCC with 179 target lesions were enrolled in phase 2 and phase 3 trials of VEGF-targeted therapies and retrospectively studied with Institutional Review Board approval. Two radiologists independently measured the long axis diameter and mean attenuation of target lesions at baseline and on follow-up CT. Concordance correlation coefficients and Bland-Altman plots were used to assess intraobserver and interobserver agreement. RESULTS: High concordance correlation coefficients (range, 0.8602-0.9984) were observed in all types of measurements. The 95% limits of agreement for the percentage change of the sum longest diameter was -7.30% to 7.86% for intraobserver variability, indicating that 10% tumor shrinkage represents a true change in tumor size when measured by a single observer. The 95% limits of interobserver variability were -16.3% to 15.4%. On multivariate analysis, the location of the lesion was found to significantly contribute to interobserver variability (P = .048). The 95% limits of intraobserver agreement for the percentage change in CT attenuation were -18.34% to 16.7%. CONCLUSIONS: In patients with mRCC who are treated with VEGF inhibitors, 10% tumor shrinkage is a reproducible radiologic response indicator when baseline and follow-up studies are measured by a single radiologist. Lesion location contributes significantly to measurement variability and should be considered when selecting target lesions.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Carcinoma de Células Renais
/
Tomografia Computadorizada por Raios X
/
Inibidores da Angiogênese
/
Neoplasias Renais
Tipo de estudo:
Observational_studies
/
Prognostic_studies
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2014
Tipo de documento:
Article