Your browser doesn't support javascript.
loading
Learning from unbalanced data: a cascade-based approach for detecting clustered microcalcifications.
Bria, A; Karssemeijer, N; Tortorella, F.
Afiliação
  • Bria A; Department of Electrical and Information Engineering, University of Cassino and L.M., Via Di Biasio 43, 03043 Cassino (FR), Italy. Electronic address: a.bria@unicas.it.
  • Karssemeijer N; Diagnostic Image Analysis Group, Radboud University Nijmegen Medical Centre, P.O. Box 9102, 6500 HC Nijmegen, The Netherlands. Electronic address: n.karssemeijer@rad.umcn.nl.
  • Tortorella F; Department of Electrical and Information Engineering, University of Cassino and L.M., Via Di Biasio 43, 03043 Cassino (FR), Italy. Electronic address: tortorella@unicas.it.
Med Image Anal ; 18(2): 241-52, 2014 Feb.
Article em En | MEDLINE | ID: mdl-24292553
ABSTRACT
Finding abnormalities in diagnostic images is a difficult task even for expert radiologists because the normal tissue locations largely outnumber those with suspicious signs which may thus be missed or incorrectly interpreted. For the same reason the design of a Computer-Aided Detection (CADe) system is very complex because the large predominance of normal samples in the training data may hamper the ability of the classifier to recognize the abnormalities on the images. In this paper we present a novel approach for computer-aided detection which faces the class imbalance with a cascade of boosting classifiers where each node is trained by a learning algorithm based on ranking instead of classification error. Such approach is used to design a system (CasCADe) for the automated detection of clustered microcalcifications (µCs), which is a severely unbalanced classification problem because of the vast majority of image locations where no µC is present. The proposed approach was evaluated with a dataset of 1599 full-field digital mammograms from 560 cases and compared favorably with the Hologic R2CAD ImageChecker, one of the most widespread commercial CADe systems. In particular, at the same lesion sensitivity of R2CAD (90%) on biopsy proven malignant cases, CasCADe and R2CAD detected 0.13 and 0.21 false positives per image (FPpi), respectively (p-value=0.09), whereas at the same FPpi of R2CAD (0.21), CasCADe and R2CAD detected 93% and 90% of true lesions respectively (p-value=0.11) thus showing that CasCADe can compete with high-end CADe commercial systems.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Calcinose / Mamografia / Interpretação de Imagem Radiográfica Assistida por Computador / Intensificação de Imagem Radiográfica Limite: Female / Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Calcinose / Mamografia / Interpretação de Imagem Radiográfica Assistida por Computador / Intensificação de Imagem Radiográfica Limite: Female / Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article