Your browser doesn't support javascript.
loading
Diagnostic accuracy of dynamic gadoxetic-acid-enhanced MRI and PET/CT compared in patients with liver metastases from neuroendocrine neoplasms.
Armbruster, Marco; Zech, Christoph J; Sourbron, Steven; Ceelen, Felix; Auernhammer, Christoph J; Rist, Carsten; Haug, Alexander; Singnurkar, Amit; Reiser, Maximilian F; Sommer, Wieland H.
Afiliação
  • Armbruster M; Department of Clinical Radiology, University Hospitals-Grosshadern, Ludwig-Maximilians University, Munich, Germany.
J Magn Reson Imaging ; 40(2): 457-66, 2014 Aug.
Article em En | MEDLINE | ID: mdl-24347148
PURPOSE: To evaluate the diagnostic accuracy of dynamic-contrast-enhanced (DCE) MRI in comparison to both (18)F-FDG- and (68)Ga-DOTATATE-PET/CT in patients with liver metastases of neuroendocrine neoplasms (NEN). MATERIALS AND METHODS: Thirty-two patients with hepatic metastases from NEN were examined both in DCE-MRI and positron emission tomography/computed tomography (PET/CT), using either (18)F-fluorodeoxyglucose ((18)F-FDG) or (68)Ga-DOTATATE as tracer. DCE-MRI was performed at 3 Tesla with Gd-EOB-DTPA acquiring 48 slices every 2.2 s for 5 min. Three regions of interest (ROIs) representing liver background and liver metastases were defined in fat-saturated T1w three-dimensional GRE MRI sequences in the hepatobiliary phase. Corresponding ROIs were then defined in the DCE-MRI- and in the PET/CT-dataset. Area under the curve (AUC) was calculated for the differentiation between metastases and liver background for DCE-MRI and PET-CT parameters. RESULTS: AUC was very high for SUVmean (mean standardized uptake value) derived from (68)Ga-DOTATATE- (AUC = 0.966), and (18)F-FDG-PET/CT (AUC = 0.989). For DCE-MRI parameters, arterial flow fraction and intracellular uptake fraction showed the highest AUCs (AUC = 0.826, AUC = 0.819, respectively). The combination of those two had an AUC of 0.949. The combination of DCE-MRI and PET-CT parameters resulted in the highest AUC. CONCLUSION: Both PET/CT parameters and DCE-MRI perfusion parameters show a high diagnostic accuracy in the distinction between liver metastases and liver tissue. Our data suggest that both modalities provide complementary information.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Tumores Neuroendócrinos / Gadolínio DTPA / Tomografia por Emissão de Pósitrons / Neoplasias Hepáticas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Tumores Neuroendócrinos / Gadolínio DTPA / Tomografia por Emissão de Pósitrons / Neoplasias Hepáticas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article