Your browser doesn't support javascript.
loading
Focus: a robust workflow for one-dimensional NMR spectral analysis.
Alonso, Arnald; Rodríguez, Miguel A; Vinaixa, Maria; Tortosa, Raül; Correig, Xavier; Julià, Antonio; Marsal, Sara.
Afiliação
  • Alonso A; Rheumatology Research Group, Vall d'Hebron Hospital Research Institute , Barcelona, Spain.
Anal Chem ; 86(2): 1160-9, 2014 Jan 21.
Article em En | MEDLINE | ID: mdl-24354303
ABSTRACT
One-dimensional (1)H NMR represents one of the most commonly used analytical techniques in metabolomic studies. The increase in the number of samples analyzed as well as the technical improvements involving instrumentation and spectral acquisition demand increasingly accurate and efficient high-throughput data processing workflows. We present FOCUS, an integrated and innovative methodology that provides a complete data analysis workflow for one-dimensional NMR-based metabolomics. This tool will allow users to easily obtain a NMR peak feature matrix ready for chemometric analysis as well as metabolite identification scores for each peak that greatly simplify the biological interpretation of the results. The algorithm development has been focused on solving the critical difficulties that appear at each data processing step and that can dramatically affect the quality of the results. As well as method integration, simplicity has been one of the main objectives in FOCUS development, requiring very little user input to perform accurate peak alignment, peak picking, and metabolite identification. The new spectral alignment algorithm, RUNAS, allows peak alignment with no need of a reference spectrum, and therefore, it reduces the bias introduced by other alignment approaches. Spectral alignment has been tested against previous methodologies obtaining substantial improvements in the case of moderate or highly unaligned spectra. Metabolite identification has also been significantly improved, using the positional and correlation peak patterns in contrast to a reference metabolite panel. Furthermore, the complete workflow has been tested using NMR data sets from 60 human urine samples and 120 aqueous liver extracts, reaching a successful identification of 42 metabolites from the two data sets. The open-source software implementation of this methodology is available at http//www.urr.cat/FOCUS.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Software / Espectroscopia de Ressonância Magnética / Metaboloma / Fígado Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Software / Espectroscopia de Ressonância Magnética / Metaboloma / Fígado Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article