Your browser doesn't support javascript.
loading
Abatement of xenon and iodine emissions from medical isotope production facilities.
Doll, Charles G; Sorensen, Christina M; Bowyer, Theodore W; Friese, Judah I; Hayes, James C; Hoffmann, Emmy; Kephart, Rosara.
Afiliação
  • Doll CG; Pacific Northwest National Laboratory, Richland, WA 99354, USA. Electronic address: charles.doll@pnnl.gov.
  • Sorensen CM; Pacific Northwest National Laboratory, Richland, WA 99354, USA.
  • Bowyer TW; Pacific Northwest National Laboratory, Richland, WA 99354, USA.
  • Friese JI; Pacific Northwest National Laboratory, Richland, WA 99354, USA.
  • Hayes JC; Pacific Northwest National Laboratory, Richland, WA 99354, USA.
  • Hoffmann E; Australian Nuclear Science and Technology Organization, Menai, Australia.
  • Kephart R; Pacific Northwest National Laboratory, Richland, WA 99354, USA.
J Environ Radioact ; 130: 33-43, 2014 Apr.
Article em En | MEDLINE | ID: mdl-24418952
ABSTRACT
The capability of the International Monitoring System (IMS) to detect xenon from underground nuclear explosions is dependent on the radioactive xenon background. Adding to the background, medical isotope production (MIP) by fission releases several important xenon isotopes including xenon-133 and iodine-133 that decays to xenon-133. The amount of xenon released from these facilities may be equivalent to or exceed that released from an underground nuclear explosion. Thus the release of gaseous fission products within days of irradiation makes it difficult to distinguish MIP emissions from a nuclear explosion. In addition, recent shortages in molybdenum-99 have created interest and investment opportunities to design and build new MIP facilities in the United States and throughout the world. Due to the potential increase in the number of MIP facilities, a discussion of abatement technologies provides insight into how the problem of emission control from MIP facilities can be tackled. A review of practices is provided to delineate methods useful for abatement of medical isotopes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos de Xenônio / Poluentes Radioativos do Ar / Contaminação Radioativa do Ar / Recuperação e Remediação Ambiental / Radioisótopos do Iodo Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos de Xenônio / Poluentes Radioativos do Ar / Contaminação Radioativa do Ar / Recuperação e Remediação Ambiental / Radioisótopos do Iodo Idioma: En Ano de publicação: 2014 Tipo de documento: Article