Investigation of the sample preparation and curing treatment effects on mechanical properties and bioactivity of silica rich metakaolin geopolymer.
Catauro, M; Bollino, F; Papale, F; Lamanna, G.
Afiliação
  • Catauro M; Department of Industrial and Information Engineering, Second University of Naples, Via Roma 29, 81031 Aversa, Italy. Electronic address: michelina.catauro@unina2.it.
  • Bollino F; Department of Industrial and Information Engineering, Second University of Naples, Via Roma 29, 81031 Aversa, Italy.
  • Papale F; Department of Industrial and Information Engineering, Second University of Naples, Via Roma 29, 81031 Aversa, Italy.
  • Lamanna G; Department of Industrial and Information Engineering, Second University of Naples, Via Roma 29, 81031 Aversa, Italy.
Mater Sci Eng C Mater Biol Appl ; 36: 20-4, 2014 Mar 01.
Article em En | MEDLINE | ID: mdl-24433882
ABSTRACT
In many biomedical applications both the biological and mechanical behaviours of implants are of relevant interest; in the orthopaedic field, for example, favourable bioactivity and biocompatibility capabilities are necessary, but at the same time the mechanical characteristics of the implants must be such as to allow one to support the body weight. In the present work, the authors have examined the application of geopolymers with composition H24AlK7Si31O79 and ratio Si/Al=31 to be used in biomedical field, considering two different preparation

methods:

one of the activators (KOH) has been added as pellets in the potassium silicate solution, in the other as a water solution with 8M concentration. Moreover, a different water content was used and only some of the synthesized samples were heat treated. The chemical and microstructural characterizations of those materials have been carried out by Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM). Subsequently, the effects of the adopted preparation on the mechanical and biological properties have been studied compressive strength tests have demonstrated that more fragile specimens were obtained when KOH was added as a solution. The bioactivity was successfully evaluated with the soaking of the samples in a simulated body fluid (SBF) for 3 weeks. The formation of a layer of hydroxyapatite on the surface of the materials has been shown both by SEM micrographs and EDS analyses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Materiais Biocompatíveis / Teste de Materiais / Dióxido de Silício / Fenômenos Mecânicos / Caulim Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Materiais Biocompatíveis / Teste de Materiais / Dióxido de Silício / Fenômenos Mecânicos / Caulim Idioma: En Ano de publicação: 2014 Tipo de documento: Article