Characteristics of electrically injured skin from human hand tissue samples using Fourier transform infrared microspectroscopy.
Li, Shi-Ying; Zou, Dong-Hua; Luo, Yi-Wen; Sun, Qi-Ran; Deng, Kai-Fei; Chen, Yi-Jiu; Huang, Ping.
Afiliação
  • Li SY; Department of Forensic Pathology, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China; Department of Forensic Medicine, Shanghai Medical College, Fudan University, 200032, Shanghai, P.R. China.
  • Zou DH; Department of Forensic Pathology, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China.
  • Luo YW; Shanghai Key Laboratory of Forensic Medicine, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China.
  • Sun QR; Shanghai Key Laboratory of Forensic Medicine, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China.
  • Deng KF; Shanghai Key Laboratory of Forensic Medicine, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China.
  • Chen YJ; Department of Forensic Pathology, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China. Electronic address: yijiuchen@gmail.com.
  • Huang P; Department of Forensic Pathology, Institute of Forensic Science, Ministry of Justice, 200063, Shanghai, P.R. China. Electronic address: huangpingifs@gmail.com.
Sci Justice ; 54(1): 98-104, 2014 Jan.
Article em En | MEDLINE | ID: mdl-24438785
This technical note describes a method for distinguishing normal skin tissue samples from those electrically injured by Fourier transform infrared microspectroscopy (FTIR MSP). Furthermore, the infrared spectral features of electrically injured cells and tissues were evaluated to identify molecular changes in epidermal cells. In the present study, 20 human hand tissue samples were evaluated macroscopically and histopathologically. The electrically injured skin samples were subdivided into 2 regions [normal cell regions (NCRs) and polarized cell regions (PCRs)] and 14 major spectral absorption bands were selected. The spectral results showed that the band absorbance at 1080, 1126, 1172, 1242, 1307, 1403, 1456, 1541, 2852, 2925, 2957, 3075, and 3300cm(-1) increased significantly both in the stratum and non-stratum corneum of the PCRs in electrically injured skin tissues samples. No significant difference was found between normal skin and the NCR of the electrically injured skin samples. The band absorbance ratios of A1172/A1126, A1456/A1403, and A2925/A2957 were significantly increased, whereas the A1652/A1541 ratio was decreased in the PCR of the stratum corneum and non-stratum corneum. Baseline changes from 4000 to near 1737cm(-1) were observed in the spectra of the electrically injured skin samples, which were interpreted in terms of the pathological process involved in electrical injury. FTIR-MSP presents a useful method to provide objective spectral markers for the assisted diagnosis of electrical marks.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Espectroscopia de Infravermelho com Transformada de Fourier / Traumatismos por Eletricidade Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Espectroscopia de Infravermelho com Transformada de Fourier / Traumatismos por Eletricidade Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article