Diagnostic accuracy of the faecal immunochemical test for colorectal cancer in symptomatic patients: comparison with NICE and SIGN referral criteria.
Cubiella, J; Salve, M; Díaz-Ondina, M; Vega, P; Alves, M T; Iglesias, F; Sánchez, E; Macía, P; Blanco, I; Bujanda, L; Fernández-Seara, J.
Afiliação
  • Cubiella J; Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense, Spain.
Colorectal Dis ; 16(8): O273-82, 2014 Aug.
Article em En | MEDLINE | ID: mdl-24456168
AIM: The diagnostic accuracy of the faecal immunochemical test (FIT) at a 100 ng/ml threshold for colorectal cancer (CRC) was compared with National Institute for Health and Care Excellence (NICE) and the Scottish Intercollegiate Guidelines Network (SIGN) referral criteria. METHOD: A multicentre, prospective, blind study of diagnostic tests was carried out in two Spanish health areas. In 787 symptomatic patients referred for a diagnostic colonoscopy, we determined whether patients met NICE and SIGN referral criteria. All patients performed one FIT determination (OCsensor(™) ). The sensitivity and specificity for CRC detection were determined with McNemar's test. The diagnostic odds ratio as well as the number needed to scope (NNS) to detect a CRC were calculated. RESULTS: We detected CRC in 97 (12.3%) patients; 241 (30.6%) had an FIT ≥ 100 ng/ml and 300 (38.1%) and 473 (60.1%) met NICE and SIGN referral criteria. The FIT had a higher sensitivity for CRC detection than NICE criteria (87.6%, 61.9%; P < 0.001) and SIGN criteria (82.5%; P = 0.4). The specificity of FIT was also higher than NICE and SIGN criteria (77.4%, 65.2%, 42.7%; P < 0.001). The odds ratios of FIT, NICE and SIGN criteria for the diagnosis of CRC were 24.24 (95% CI 12.91-45.53), 3.04 (95% CI 1.96-4.71) and 3.51 (95% CI 2.03-6.06). The NNS to detect a CRC in individuals with an FIT ≥ 100 ng/ml was 2.83 (95% CI 2.4-3.41) and in individuals who met NICE and SIGN criteria it was 5 (95% CI 3.98-6.37) and 5.95 (95% CI 4.85-7.35). CONCLUSION: Our study suggests that FIT is more accurate for the detection of CRC than the current NICE and SIGN referral criteria in symptomatic patients referred for colonoscopy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Biomarcadores Tumorais / Testes Diagnósticos de Rotina / Fezes Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Screening_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Biomarcadores Tumorais / Testes Diagnósticos de Rotina / Fezes Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Screening_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2014 Tipo de documento: Article