Your browser doesn't support javascript.
loading
Changes in exhaled nitric oxide after inhalation challenge with occupational agents.
Sastre, J; Costa, C; del Garcia Potro, M; Aguado, E; Mahillo, I; Fernández-Nieto, M.
Afiliação
  • Sastre J; Allergy Department, Fundación Jiménez Díaz and CIBER de Enfermedades Respiratorias (CIBERES) Madrid, Spain jsastre@fjd.es
  • Costa C; Allergy Department, Fundación Jiménez Díaz and CIBER de Enfermedades Respiratorias (CIBERES) Madrid, Spain
  • del Garcia Potro M; Allergy Department, Fundación Jiménez Díaz and CIBER de Enfermedades Respiratorias (CIBERES) Madrid, Spain
  • Aguado E; Allergy Department, Fundación Jiménez Díaz and CIBER de Enfermedades Respiratorias (CIBERES) Madrid, Spain
  • Mahillo I; Epidemiology Department, Fundación Jiménez Díaz, Madrid, Spain.
  • Fernández-Nieto M; Allergy Department, Fundación Jiménez Díaz and CIBER de Enfermedades Respiratorias (CIBERES) Madrid, Spain
Article em En | MEDLINE | ID: mdl-24459819
BACKGROUND AND OBJECTIVE: The use of fractional exhaled nitric oxide (FeNO) concentration has been proposed as a surrogate marker for monitoring airway response to specific inhalation challenge (SIC). We investigated the usefulness of FeNO measurements for monitoring airway response to SIC with occupational agents. Materialandmethods: Workers with suspected occupational asthma were recruited to undergo SIC with occupational agents and subsequently FeNO testing at baseline and 24 hours. RESULTS: Sixty-eight patients were evaluated, 45 of whom had a positive SIC. SIC-positive patients showed a significant increase in FeNO 24 hours postchallenge, with an increase ratio of 1.25 (95% CI, 1.05-1.48; P=.01); no increase was seen in patients with a negative SIC (P=.08). The predictive capacity of variations in FeNO showed that for each unit increase in FeNO, the probability of a positive SIC rose by 4%. A baseline FeNO value of 25 ppb predicted a positive SIC with 60% sensitivity and 80% specificity. The increase in %FeNO cutoff point providing maximal sensitivity and specificity for predicting a positive SIC was 41% (sensitivity 50%, specificity 95%). CONCLUSIONS: We demonstrated that asthmatic reactions induced by occupational agents during SICs are associated with a consistent increase in FeNO. However, the predictive diagnostic capacity of FeNO measurements is low. While FeNO may aid in the interpretation of SIC in some cases, it cannot be used as a general surrogate marker to predict or to assess SICs with occupational agents.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes Respiratórios / Hiper-Reatividade Brônquica / Asma Ocupacional / Óxido Nítrico Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2013 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes Respiratórios / Hiper-Reatividade Brônquica / Asma Ocupacional / Óxido Nítrico Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2013 Tipo de documento: Article