Your browser doesn't support javascript.
loading
Evaluation of the Petrifilm™ EB and TEMPO(®) EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk.
Cirolini, Andréia; Miotto, Marília; Machado, Fernanda Morgana; da Silva, Helen Silvestre; Ogliari, Paulo José; Vieira, Cleide Rosana Werneck.
Afiliação
  • Cirolini A; Departamento de Ciência e Tecnologia de Alimentos, Centro de Ciências Agrárias, Universidade Federal de Santa Catarina, Brazil.
  • Miotto M; Departamento de Ciência e Tecnologia de Alimentos, Centro de Ciências Agrárias, Universidade Federal de Santa Catarina, Brazil.
  • Machado FM; Departamento de Ciência e Tecnologia de Alimentos, Centro de Ciências Agrárias, Universidade Federal de Santa Catarina, Brazil.
  • da Silva HS; Departamento de Ciência e Tecnologia de Alimentos, Centro de Ciências Agrárias, Universidade Federal de Santa Catarina, Brazil.
  • Ogliari PJ; Departamento de Informática e Estatística, Centro de Tecnologia, Universidade Federal de Santa Catarina, Brazil.
  • Vieira CR; Departamento de Ciência e Tecnologia de Alimentos, Centro de Ciências Agrárias, Universidade Federal de Santa Catarina, Brazil.
Braz J Microbiol ; 44(3): 771-5, 2013.
Article em En | MEDLINE | ID: mdl-24516444
ABSTRACT
The development of alternative microbiological techniques is driven by the necessity to meet the current needs to deliver rapid results in the manufacturing process of foods, but it is important that these methods be evaluated for each application. The objective of the present study was to assess the Petrifilm™ EB and the TEMPO(®) EB systems with ISO 21528-22004 for the count of Enterobacteriaceae in pasteurized and UHT milk samples. We analyzed the microflora of 141 pasteurized milk samples, 15 samples of artificially contaminated pasteurized milk and 15 samples of artificially contaminated UHT milk. Investigation of the method Petrifilm™ EB and ISO 215282 regression analysis showed a high correlation in the samples, r = 0.90 for the microflora of pasteurized milk, r = 0.98 for artificially contaminated pasteurized milk and r = 0.99 for the artificially contaminated UHT milk. In evaluating the system TEMPO EB ® method and ISO 215282 correlation was also significant in the analyzed samples, with r = 0.86 for the microflora of pasteurized milk, r = 0.96 for artificially contaminated pasteurized milk and r = 0.99 for artificially contaminated UHT milk. No statistically significant differences were observed between the three methods conducted to analyze artificially contaminated pasteurized and UHT milk at three inoculum levels. In conclusion, the Petrifilm™ EB system and the TEMPO(®) EB system may be an alternative to the ISO 21528-22004 for the Enterobacteriaceae assay for milk as because of the ease-of-operation and the time reduction achieved for conducting the microbiological assay using these systems.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Leite / Enterobacteriaceae / Carga Bacteriana / Microbiologia de Alimentos Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Leite / Enterobacteriaceae / Carga Bacteriana / Microbiologia de Alimentos Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Ano de publicação: 2013 Tipo de documento: Article