Your browser doesn't support javascript.
loading
On-line headspace-multicapillary column-ion mobility spectrometry hyphenation as a tool for the determination of off-flavours in foods.
Márquez-Sillero, Isabel; Cárdenas, Soledad; Sielemann, Stefanie; Valcárcel, Miguel.
Afiliação
  • Márquez-Sillero I; Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building (Annex), Campus de Rabanales, University of Córdoba, E-14071 Córdoba, Spain; G.A.S.,Gesellschaft für Analytische Sensorsysteme mbH, Otto-Hahn-Str. 15, 44229 Dortmund, Germany.
  • Cárdenas S; Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building (Annex), Campus de Rabanales, University of Córdoba, E-14071 Córdoba, Spain.
  • Sielemann S; G.A.S.,Gesellschaft für Analytische Sensorsysteme mbH, Otto-Hahn-Str. 15, 44229 Dortmund, Germany.
  • Valcárcel M; Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building (Annex), Campus de Rabanales, University of Córdoba, E-14071 Córdoba, Spain. Electronic address: qa1vacam@uco.es.
J Chromatogr A ; 1333: 99-105, 2014 Mar 14.
Article em En | MEDLINE | ID: mdl-24529959
ABSTRACT
In this work, an ion mobility spectrometer (IMS) with a tritium ionization source on-line coupled to a headspace (HS) autosampler and a multicapillary column (MCC) was evaluated for the monitoring of lipid oxidation products in milk with different flavours (cacao, fruits, cereals and nuts) and linseed oil samples enriched with omega-3 acids. In this combination, the multicapillary column is used as an interface between the HS and the IMS, providing the efficient separation of the volatile compounds. In this way, the proposed method permits the detection of hexanal, 2-butanone, acetone and dimethyl sulfide as representative degradation products. The limits of detection were in the interval 0.3 µg L(-1) (for hexanal in milk) to 3.0 µg L(-1) (for dimethyl sulfide in linseed oil) while the limits of quantification varied between 1.1 µg L(-1) (for hexanal in milk) and 9.6 µg L(-1) (for dimethyl sulfide in linseed oil). The precision of the method was evaluated as relative standard deviation and the values were better than 8% in all cases. The evolution of the volatiles profile during 36 days under different storage conditions (temperature, oxygen and light) demonstrates the capability of the HS-MCC-IMS coupling for the estimation of the degradation of the samples. After the degradation study, it can be concluded that the stability of the milk samples during storage is more affected by the light while temperature was more critical for oil samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral / Análise de Alimentos Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral / Análise de Alimentos Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article