Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.
Lesperance, Marielle; Martinov, M; Thomson, R M.
Afiliação
  • Lesperance M; Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6, Canada.
  • Martinov M; Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6, Canada.
  • Thomson RM; Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6, Canada.
Med Phys ; 41(3): 031706, 2014 Mar.
Article em En | MEDLINE | ID: mdl-24593710
PURPOSE: To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS: Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including plaques consisting of a stainless steel backing and acrylic insert, and gold alloy backings with: short collimating lips and acrylic insert, no lips and silicone polymer insert, no lips and a thin acrylic layer, and individual collimating slots for each seed within the backing and no insert. Monte Carlo simulations are performed using the EGSnrc user-code BrachyDose for single and multiple seed configurations for the plaques in water and within an eye model (including nonwater media). Simulations under TG-43 assumptions are also performed, i.e., with the same seed configurations in water, neglecting interseed and plaque effects. Maximum and average doses to ocular structures as well as isodose contours are compared for simulations of each radionuclide within the plaque models. RESULTS: The presence of the plaque affects the dose distribution substantially along the plaque axis for both single seed and multiseed simulations of each plaque design in water. Of all the plaque models, the COMS plaque generally has the largest effect on the dose distribution in water along the plaque axis. Differences between doses for single and multiple seed configurations vary between plaque models and radionuclides. Collimation is most substantial for the plaque with individual collimating slots. For plaques in the full eye model, average dose in the tumor region differs from those for the TG-43 simulations by up to 10% for(125)I and (131)Cs, and up to 17% for (103)Pd, and in the lens region by up to 29% for (125)I, 34% for (103)Pd, and 28% for (131)Cs. For the same prescription dose to the tumor apex, the lowest doses to critical ocular structures are generally delivered with plaques containing (103)Pd seeds. CONCLUSIONS: The combined effects of ocular and plaque media on dose are significant and vary with plaque model and radionuclide, suggesting the importance of model-based dose calculations employing accurate ocular and plaque media and geometries for eye plaque brachytherapy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Radiometria / Braquiterapia / Imagens de Fantasmas / Neoplasias Oculares Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Radiometria / Braquiterapia / Imagens de Fantasmas / Neoplasias Oculares Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article