Your browser doesn't support javascript.
loading
Development and validation of high-performance size exclusion chromatography methods to determine molecular size parameters of Haemophilus influenzae type b polysaccharides and conjugates.
Thiébaud, Jérôme; Fanget, Ingrid; Jaudinaud, Isabelle; Fourrichon, Laurence; Sabouraud, Alain; Talaga, Philippe; Uhlrich, Sylvie.
Afiliação
  • Thiébaud J; Analytical Research Department, SanofiPasteur, 69280 Marcy l'Étoile, France. Electronic address: jerome.thiebaud@sanofipasteur.com.
  • Fanget I; Analytical Research Department, SanofiPasteur, 69280 Marcy l'Étoile, France.
  • Jaudinaud I; Analytical Research Department, SanofiPasteur, 69280 Marcy l'Étoile, France.
  • Fourrichon L; Discovery Department, Sanofi Pasteur, 69280 Marcy l'Étoile, France.
  • Sabouraud A; Chief Medical Office, Sanofi Pasteur, 69280 Marcy l'Étoile, France.
  • Talaga P; Analytical Research Department, SanofiPasteur, 69280 Marcy l'Étoile, France.
  • Uhlrich S; Strategic Alignment and Expertise Department, Sanofi Pasteur, 69280 Marcy l'Étoile, France.
Anal Biochem ; 453: 22-8, 2014 May 15.
Article em En | MEDLINE | ID: mdl-24608090
Current vaccines against Haemophilus influenzae type b (Hib) consist of the polyribosyl ribitol phosphate (PRP) capsular polysaccharide chemically conjugated to a carrier protein. Among the various biological and physical analyses to be performed on these vaccines, the determination of the molecular size of the polysaccharide preparations throughout the conjugation process is particularly relevant. Comparison of results from high-performance size exclusion chromatography (HPSEC) with those routinely obtained using conventional gel permeation chromatography (CGPC) methods highlights the correlation between the two methods for determining the values of the chromatographic distribution coefficient (KD) of native and activated polysaccharides. The resulting data showed that the KD value is sufficient to characterize these polysaccharides using an HPSEC method. However, additional molecular size parameters (i.e., molar mass and hydrodynamic radius) are necessary for a reliable characterization of the tetanus conjugate (PRP-T), certainly due to the lattice-like structure of the conjugate. In practice, an absolute detection system in HPSEC composed of a low-angle light scattering detector, a viscometer, and a refractive index (RI) detector was used. As demonstrated, these HPSEC methods are rapid, accurate, and reproducible for the polysaccharides and their glycoconjugates and provide a relevant and more informative alternative to the current CGPC methods.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polissacarídeos / Glicoconjugados / Cromatografia em Gel / Haemophilus influenzae tipo b Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polissacarídeos / Glicoconjugados / Cromatografia em Gel / Haemophilus influenzae tipo b Idioma: En Ano de publicação: 2014 Tipo de documento: Article