Your browser doesn't support javascript.
loading
Optical coherence tomography-guided retinal prosthesis design: model of degenerated retinal curvature and thickness for patient-specific devices.
Opie, Nicholas L; Ayton, Lauren N; Apollo, Nicholas V; Ganesan, Kumaravelu; Guymer, Robyn H; Luu, Chi D.
Afiliação
  • Opie NL; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, The University of Melbourne, Melbourne, Victoria, Australia.
Artif Organs ; 38(6): E82-94, 2014 Jun.
Article em En | MEDLINE | ID: mdl-24689741
ABSTRACT
Retinitis pigmentosa affects over 1.5 million people worldwide and is a leading cause of vision loss and blindness. While retinal prostheses have shown some success in restoring basic levels of vision, only generic, "one-size-fits-all" devices are currently being implanted. In this study, we used optical coherence tomography scans of the degenerated retina from 88 patients with retinitis pigmentosa to generate models of retinal thickness and curvature for the design of customized implants. We found the average retinal thickness at the fovea to be 152.9 ± 61.3 µm, increasing to a maximum retinal thickness of 250.9 ± 57.5 µm at a nasal eccentricity of 5°. These measures could be used to assist the development of custom-made penetrating electrodes to enhance and optimize epiretinal prostheses. From the retinal thickness measurements, we determined that the optimal length of penetrating electrodes to selectively stimulate retinal ganglion cell bodies and interneuron axons in the ganglion cell layer should be 30-100 µm, and to preferentially stimulate interneurons in the inner nuclear layer, electrodes should be 100-200 µm long. Electrodes greater than 200 µm long had the potential to penetrate through the retina into the choroid, which could cause devastating complications to the eye and should be avoided. The two- and three-dimensional models of retinal thickness developed in this study can be used to design patient-specific epiretinal implants that will help with safety and to optimize the efficacy of neuronal stimulation, ensuring the best functional performance of the device for patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Retina / Retinose Pigmentar / Desenho Assistido por Computador / Implantação de Prótese / Tomografia de Coerência Óptica / Próteses Visuais Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Retina / Retinose Pigmentar / Desenho Assistido por Computador / Implantação de Prótese / Tomografia de Coerência Óptica / Próteses Visuais Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article