Your browser doesn't support javascript.
loading
Guidance for accurate and consistent tissue Doppler velocity measurement: comparison of echocardiographic methods using a simple vendor-independent method for local validation.
Dhutia, Niti M; Zolgharni, Massoud; Willson, Keith; Cole, Graham; Nowbar, Alexandra N; Dawson, David; Zielke, Sayeh; Whelan, Carol; Newton, Jim; Mayet, Jamil; Manisty, Charlotte H; Francis, Darrel P.
Afiliação
  • Dhutia NM; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK nitidhutia@gmail.com.
  • Zolgharni M; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK.
  • Willson K; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK.
  • Cole G; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK.
  • Nowbar AN; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK.
  • Dawson D; Hammersmith Hospital, Imperial College NHS Trust, London, UK.
  • Zielke S; Oxford University Hospitals NHS Trust, Oxford, UK.
  • Whelan C; Royal Free London NHS Foundation Trust, London, UK.
  • Newton J; Oxford University Hospitals NHS Trust, Oxford, UK.
  • Mayet J; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK.
  • Manisty CH; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK.
  • Francis DP; International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, 59-61 North Wharf Road, London W2 1LA, UK.
Eur Heart J Cardiovasc Imaging ; 15(7): 817-27, 2014 Jul.
Article em En | MEDLINE | ID: mdl-24699322

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Fluxometria por Laser-Doppler / Guias como Assunto / Ecocardiografia Doppler de Pulso / Imagens de Fantasmas Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Fluxometria por Laser-Doppler / Guias como Assunto / Ecocardiografia Doppler de Pulso / Imagens de Fantasmas Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article