Your browser doesn't support javascript.
loading
Combined intravoxel incoherent motion and diffusion tensor imaging of renal diffusion and flow anisotropy.
Notohamiprodjo, Mike; Chandarana, Hersh; Mikheev, Artem; Rusinek, Henry; Grinstead, John; Feiweier, Thorsten; Raya, José G; Lee, Vivian S; Sigmund, Eric E.
Afiliação
  • Notohamiprodjo M; Center for Biomedical Imaging, Department of Radiology, NYU Langone Medical Center, New York, New York, USA; Department of Clinical Radiology, University Hospitals Munich, Munich, Germany; Department of Radiology, University Hospital Tuebingen, Tuebingen, Germany.
Magn Reson Med ; 73(4): 1526-32, 2015 Apr.
Article em En | MEDLINE | ID: mdl-24752998
PURPOSE: We used a combined intravoxel incoherent motion-diffusion tensor imaging (IVIM-DTI) methodology to distinguish structural from flow effects on renal diffusion anisotropy. METHODS: Eight volunteers were examined with IVIM-DTI at 3T with 20 diffusion directions and 10 b-values. Mean diffusivity (MD) and fractional anisotropy (FA) from DTI analysis were calculated for low (b ≤ 200 s/mm(2) ), high (b > 200 s/mm(2) ), and full b-value ranges. IVIM-parameters perfusion-fraction fP , pseudo-diffusivity Dp , and tissue-diffusivity Dt were first calculated independently on a voxelwise basis for all directions. After estimating a fixed isotropic fp from these data, global anisotropies of Dt and Dp in the cortex and medulla were determined in a constrained cylindrical description and visualized using polar plots and cosine scatterplots. RESULTS: For all b-value ranges, medullary FA was significantly higher than that of the cortex. The corticomedullary difference was smaller for the high b-value range. Significantly higher fp and Dt were determined for the cortex and showed a significantly higher directional variance in the medulla. Polar plot analysis displayed nearly isotropic Dp and Dt in the cortex and anisotropy in the medulla. CONCLUSION: Both flow and microstructure apparently contribute to the medullary diffusion anisotropy. The described novel method may be useful in separating decreased tubular flow from irreversible structural tubular damage, for example, in diabetic nephropathy or during allograft rejection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Circulação Renal / Velocidade do Fluxo Sanguíneo / Volume Sanguíneo / Interpretação de Imagem Assistida por Computador / Imagem de Tensor de Difusão / Rim Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Circulação Renal / Velocidade do Fluxo Sanguíneo / Volume Sanguíneo / Interpretação de Imagem Assistida por Computador / Imagem de Tensor de Difusão / Rim Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2015 Tipo de documento: Article