Does use of a powered ankle-foot prosthesis restore whole-body angular momentum during walking at different speeds?
D'Andrea, Susan; Wilhelm, Natalie; Silverman, Anne K; Grabowski, Alena M.
Afiliação
  • D'Andrea S; Department of Veterans Affairs, Providence VA Medical Center, Providence, RI, USA.
Clin Orthop Relat Res ; 472(10): 3044-54, 2014 Oct.
Article em En | MEDLINE | ID: mdl-24781926
ABSTRACT

BACKGROUND:

Whole-body angular momentum (H) influences fall risk, is tightly regulated during walking, and is primarily controlled by muscle force generation. People with transtibial amputations using passive-elastic prostheses typically have greater H compared with nonamputees. QUESTIONS/

PURPOSES:

(1) Do people with unilateral transtibial amputations using passive-elastic prostheses have greater sagittal and frontal plane H ranges of motion during walking compared with nonamputees and compared with using powered prostheses? (2) Does use of powered ankle-foot prostheses result in equivalent H ranges in all planes of motion compared with nonamputees during walking as a result of normative prosthetic ankle power generation?

METHODS:

Eight patients with a unilateral transtibial amputation and eight nonamputees walked 0.75, 1.00, 1.25, 1.50, and 1.75 m/s while we measured kinematics and ground reaction forces. We calculated H for participants using their passive-elastic prosthesis and a powered ankle-foot prosthesis and for nonamputees at each speed.

RESULTS:

Patients using passive-elastic prostheses had 32% to 59% greater sagittal H ranges during the affected leg stance phase compared with nonamputees at 1.00 to 1.75 m/s (p < 0.05). Patients using passive-elastic prostheses had 5% and 9% greater sagittal H ranges compared with using powered prostheses at 1.25 and 1.50 m/s, respectively (p < 0.05). Participants using passive-elastic prostheses had 29% and 17% greater frontal H ranges at 0.75 and 1.50 m/s, respectively, compared with nonamputees (p < 0.05). Surprisingly, patients using powered prostheses had 26% to 50% greater sagittal H ranges during the affected leg stance phase compared with nonamputees at 1.00 to 1.75 m/s (p < 0.05). Patients using powered prostheses also had 26% greater frontal H range compared with nonamputees at 0.75 m/s (p < 0.05).

CONCLUSIONS:

People with a transtibial amputation may more effectively regulate H at two specific walking speeds when using powered compared with passive-elastic prostheses. CLINICAL RELEVANCE Our results support the hypothesis that an ankle-foot prosthesis capable of providing net positive work during the stance phase of walking reduces sagittal plane H; future studies are needed to validate our biomechanical findings with larger numbers of patients and should determine whether powered prostheses can decrease the risk of falls in patients with a transtibial amputation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Membros Artificiais / Tíbia / Caminhada / Marcha / Amputação Cirúrgica / Amputados / Traumatismos da Perna / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Membros Artificiais / Tíbia / Caminhada / Marcha / Amputação Cirúrgica / Amputados / Traumatismos da Perna / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article