Your browser doesn't support javascript.
loading
[Left ventricular blood flow dynamics caused by ventricular premature contraction: pulsed Doppler echocardiographic study].
Sanada, J; Nakamura, K; Tokudome, M; Mawatari, K; Tanaka, Y; Onimaru, M; Tachibana, H; Kuroiwa, N; Hashimoto, S.
Afiliação
  • Sanada J; Second Department of Internal Medicine, Faculty of Medicine, Kagoshima University.
J Cardiol ; 19(1): 263-75, 1989 Mar.
Article em Ja | MEDLINE | ID: mdl-2478691
ABSTRACT
Cardiac function at the time of ventricular premature contractions (VPC) is influenced by the coupling interval or the site of those origin. Clinical and experimental studies of the effects of VPC on intracardiac pressure dynamics have been performed; however, little is known about left ventricular blood flow dynamics. This study was attempted to determine the characteristics of blood flow dynamics in respect to the site of origin of VPC using pulsed Doppler echocardiography. The subjects consisted of 18 cases with VPC but without apparent organic heart disease. Seven cases had VPCs with a left bundle branch block pattern suggesting possible origin in the right ventricle. The other 11 cases had VPCs with a right bundle branch block pattern indicating the left ventricular origin. With the probe in the apical position, the blood flow patterns of the left ventricular outflow, central and inflow tracts were examined. The results were as follows; 1. Except for one case with shortened coupling interval, all six cases with VPCs originated from the right ventricle showed preservation of left ventricular ejection flow. 2. In two of the three cases with VPC which originated from the left ventricle and with left axis deviation, systolic flow in the left ventricular central area showed "back flow" to the apex. Ejection flow at the outflow tract was markedly diminished or disappeared in all three cases. 3. In all eight cases with VPC which originated from the left ventricle and with right axis deviation, ejection flow was slightly disturbed both in the left ventricular outflow and in the central area. 4. Ejection flow volume assessed by velocity integral indicated similar dynamics as did the ejection flow velocity. 5. In left ventriculography, asynchrony due to dyskinetic motion of the anteroapical wall was observed at the times of VPCs with left axis deviation. In conclusion, the patterns of left ventricular ejection flow dynamics depend on the site of origin of VPCs. This disturbed flow is more apparent in VPCs originating from the left ventricle compared to the right ventricle. This is especially true in cases with left axis deviation, in which VPCs arise from the posterior site of the left ventricle.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia Doppler / Circulação Coronária / Complexos Cardíacos Prematuros Limite: Adolescent / Adult / Aged / Humans / Middle aged Idioma: Ja Ano de publicação: 1989 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia Doppler / Circulação Coronária / Complexos Cardíacos Prematuros Limite: Adolescent / Adult / Aged / Humans / Middle aged Idioma: Ja Ano de publicação: 1989 Tipo de documento: Article