The comparison between robotic and manual ablations in the treatment of atrial fibrillation: a systematic review and meta-analysis.
Zhang, Wenli; Jia, Nan; Su, Jinzi; Lin, Jinxiu; Peng, Feng; Niu, Wenquan.
Afiliação
  • Zhang W; Department of Cardiology, Fuzhou General Hospital of Nanjing Command, PLA, Fujian Medical University, Fuzhou, Fujian, China.
  • Jia N; Department of Cardiology, The Fourth People's Hospital of Shenzhen, Shenzhen, Guangdong, China.
  • Su J; Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China.
  • Lin J; Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China.
  • Peng F; Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China.
  • Niu W; State Key Laboratory of Medical Genomics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China; Shanghai Institute of Hypertension, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
PLoS One ; 9(5): e96331, 2014.
Article em En | MEDLINE | ID: mdl-24800808
OBJECTIVE: To examine in what aspects and to what extent robotic ablation is superior over manual ablation, we sought to design a meta-analysis to compare clinical outcomes between the two ablations in the treatment of atrial fibrillation. METHODS AND RESULTS: A literature search was conducted of PubMed and EMBASE databases before December 1, 2013. Data were extracted independently and in duplicate from 8 clinical articles and 792 patients. Effect estimates were expressed as weighted mean difference (WMD) or odds ratio (OR) and the accompanied 95% confidence interval (95% CI). Pooling the results of all qualified trials found significant reductions in fluoroscopic time (minutes) (WMD; 95% CI; P: -8.9; -12.54 to -5.26; <0.0005) and dose-area product (Gy×cm2) (WMD; 95% CI; P: -1065.66; -1714.36 to -416.96; 0.001) for robotic ablation relative to manual ablation, with evident heterogeneity (P<0.0005) and a low probability of publication bias. In subgroup analysis, great improvement of fluoroscopic time in patients with robotic ablation was consistently presented in both randomized and nonrandomized clinical trials, particularly in the former (WMD; 95% CI; P: -12.61; -15.13 to -10.09; <0.0005). Success rate of catheter ablation was relatively higher in patients with robotic ablation than with manual ablation (OR; 95% CI; P: 3.45; 0.24 to 49.0; 0.36), the difference yet exhibiting no statistical significance. CONCLUSIONS: This study confirmed and extended previous observations by quantifying great reductions of fluoroscopic time and dose-area product in patients referred for robotic ablation than for manual ablation in the treatment of atrial fibrillation, especially in randomized clinical trials.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Robótica / Ablação por Cateter Tipo de estudo: Clinical_trials / Guideline / Systematic_reviews Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Robótica / Ablação por Cateter Tipo de estudo: Clinical_trials / Guideline / Systematic_reviews Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article