Implementation and impact of ultraviolet environmental disinfection in an acute care setting.
Haas, Janet P; Menz, Jonathan; Dusza, Stephen; Montecalvo, Marisa A.
Afiliação
  • Haas JP; Westchester Medical Center Department of Infection Prevention and Control, Valhalla, NY; Department of Medicine, New York Medical College, Valhalla, NY. Electronic address: haasj@wcmc.com.
  • Menz J; Westchester Medical Center Department of Performance Management, Valhalla, NY.
  • Dusza S; Department of Epidemiology and Community Health, New York Medical College, Valhalla, NY.
  • Montecalvo MA; Westchester Medical Center Department of Infection Prevention and Control, Valhalla, NY; Department of Medicine, New York Medical College, Valhalla, NY.
Am J Infect Control ; 42(6): 586-90, 2014 Jun.
Article em En | MEDLINE | ID: mdl-24837107
BACKGROUND: Multiple-drug-resistant organisms (MDROs) and Clostridium difficile (CD) are significant problems in health care. Evidence suggests that these organisms are transmitted to patients by the contaminated environment. METHODS: This is a retrospective study of the implementation of ultraviolet environmental disinfection (UVD) following discharge cleaning of contact precautions rooms and other high-risk areas at Westchester Medical Center, a 643-bed tertiary care academic medical center. Incidence rates of hospital-acquired MDROs plus CD before and during the UVD use were evaluated using rate ratios and piecewise regression. RESULTS: The average time per UVD was 51 minutes, and machines were in use 30% of available time. UVD was used 11,389 times; 3,833 (34%) of uses were for contact precautions discharges. UVD was completed for 76% of contact precautions discharges. There was a significant 20% decrease in hospital-acquired MDRO plus CD rates during the 22-month UVD period compared with the 30-month pre-UVD period (2.14 cases/1,000 patient-days vs 2.67 cases per 1,000 patient-days, respectively; rate ratio, 0.80; 95% confidence interval: 0.73-0.88, P < .001). CONCLUSION: During the time period UVD was in use, there was a significant decrease in overall hospital-acquired MDRO plus CD in spite of missing 24% of opportunities to disinfect contact precautions rooms. This technology was feasible to use in our acute care setting and appeared to have a beneficial effect.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Bacterianas / Raios Ultravioleta / Desinfecção / Infecção Hospitalar Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Bacterianas / Raios Ultravioleta / Desinfecção / Infecção Hospitalar Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article