Magnetic resonance imaging of painful metal-on-metal total hip replacement.
Eur J Orthop Surg Traumatol
; 25(2): 313-9, 2015 Feb.
Article
em En
| MEDLINE
| ID: mdl-24906294
Consecutive patients that had primary metal-on-metal (MoM) or metal-on-polyethylene (MoP) hip arthroplasty were prospectively enrolled to this study. All operated hips were evaluated with MRI by one radiologist who was blinded to the radiographic findings and clinical symptoms. Three groups of patients were formed: (1) thirteen MoM THRs in 13 patients with groin pain (Group 1), (2) ten MoM THRs in 10 patients with no pain (Group 2), (3) five MoP THRs in 4 patients without pain (control group). Abnormal MRI findings were distributed in all groups in a balanced way, irrespective of the patients' symptoms, prostheses, or metal ion levels. Two patients from Group 1 and one patient of Group 3 (control group) were diagnosed with a large periprosthetic mass (pseudotumor).
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Imageamento por Ressonância Magnética
/
Artralgia
/
Artroplastia de Quadril
/
Próteses Articulares Metal-Metal
Tipo de estudo:
Clinical_trials
/
Observational_studies
Limite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2015
Tipo de documento:
Article