Your browser doesn't support javascript.
loading
D- and L-amino acids in Antarctic lakes: assessment of a very sensitive HPLC-MS method.
Barbaro, Elena; Zangrando, Roberta; Vecchiato, Marco; Turetta, Clara; Barbante, Carlo; Gambaro, Andrea.
Afiliação
  • Barbaro E; Department of Environmental Sciences, Informatics and Statistics, University of Venice, Ca' Foscari, Calle Larga Santa Marta 2137, 30123, Venice, Italy, barbaro@unive.it.
Anal Bioanal Chem ; 406(22): 5259-70, 2014 Sep.
Article em En | MEDLINE | ID: mdl-24961637
ABSTRACT
Amino acids represent a fraction of organic matter in marine and freshwater ecosystems, and a source of carbon, nitrogen and energy. L-Amino acids are the most common enantiomers in nature because these chiral forms are used during the biosynthesis of proteins and peptide. To the contrary, the occurrence of D-amino acids is usually linked to the presence of bacteria. We investigated the distribution of L- and D-amino acids in the lacustrine environment of Terra Nova Bay, Antarctica, in order to define their natural composition in this area and to individuate a possible relationship with primary production. A simultaneous chromatographic separation of 40 L- and D-amino acids was performed using a chiral stationary phase based on teicoplainin aglycone (CHIROBIOTIC TAG). The chromatographic separation was coupled to two different mass spectrometers--an LTQ-Orbitrap XL (Thermo Fisher Scientific) and an API 4000 (ABSciex)--in order to investigate their quantitative performance. High-performance liquid chromatography coupled with mass spectrometry methods were evaluated through the estimation of their linear ranges, repeatability, accuracy and detection and quantification limits. The high-resolution mass spectrometer LTQ-Orbitrap XL presented detection limits between 0.4 and 7 µg L (-1), while the triple quadrupole mass spectrometer API 4000 achieved the best detection limits reported in the literature for the quantification of amino acids (between 4 and 200 ng L (-1)). The most sensitive method, HPLC-API 4000, was applied to lake water samples.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Poluentes Químicos da Água / Monitoramento Ambiental / Cromatografia Líquida de Alta Pressão / Aminoácidos Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Poluentes Químicos da Água / Monitoramento Ambiental / Cromatografia Líquida de Alta Pressão / Aminoácidos Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2014 Tipo de documento: Article