In this paper, we study an interesting geometric partition problem, called optimal field splitting, which arises in Intensity-Modulated Radiation Therapy (IMRT). In current clinical practice, a multi-leaf collimator (MLC) with a maximum leaf spread constraint is used to deliver the prescribed intensity maps (IMs). However, the maximum leaf spread of an MLC may require to split a large intensity map into several overlapping sub-IMs with each being delivered separately. We develop a close-to-linear time algorithm for solving the field splitting problem while minimizing the total complexity of the resulting sub-IMs, thus improving the treatment delivery efficiency. Meanwhile, our algorithm strives to minimize the maximum beam-on time of those sub-IMs. Our basic idea is to formulate the field splitting problem as computing a shortest path in a directed acyclic graph, which expresses a special "layered" structure. The edge weights of the graph satisfy the Monge property, which enables us to solve this shortest path problem by examining only a small portion of the graph, yielding a close-to-linear time algorithm. To minimize the maximum beam-on time of the resulting sub-IMs, we consider an interesting min-max slope path problem in a monotone polygon which is solvable in linear time. The min-max slope path problem may be of interest in its own right. Experimental results based on real medical data and computer generated IMs showed that our new algorithm runs fast and produces high quality field splitting results.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2013 Tipo de documento: Article