Your browser doesn't support javascript.
loading
Multimode Kapitza-Dirac interferometry with trapped cold atoms.
Li, WeiDong; He, Tianchen; Smerzi, Augusto.
Afiliação
  • Li W; Institute of Theoretical Physics and Department of Physics, Shanxi University, 030006, Taiyuan, China.
  • He T; Institute of Theoretical Physics and Department of Physics, Shanxi University, 030006, Taiyuan, China.
  • Smerzi A; QSTAR, INO-CNR and LENS, Largo Enrico Fermi 2, 50125 Firenze, Italy.
Phys Rev Lett ; 113(2): 023003, 2014 Jul 11.
Article em En | MEDLINE | ID: mdl-25062174
We design a multimode interferometer with cold atoms confined in a harmonic trap. A first Kapitza-Dirac pulse creates several spatially addressable modes which are coherently recombined by the harmonic potential and mixed again by a second Kapitza-Dirac pulse. A phase shift among the mode is estimated by fitting the density profile or by measuring the number of atoms in each output mode. The expected sensitivity is rigorously calculated with the Fisher information and the Cramér-Rao lower bound. For the measurement of the gravitational acceleration g we predict, with typical parameters of a compact setup, a temperature independent sensitivity which can exceed, by several orders of magnitude, the sensitivity of current atomic interferometers.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2014 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2014 Tipo de documento: Article