Your browser doesn't support javascript.
loading
An automated system using spatial oversampling for optical mapping in murine atria. Development and validation with monophasic and transmembrane action potentials.
Yu, Ting Yue; Syeda, Fahima; Holmes, Andrew P; Osborne, Benjamin; Dehghani, Hamid; Brain, Keith L; Kirchhof, Paulus; Fabritz, Larissa.
Afiliação
  • Yu TY; Centre for Cardiovascular Sciences, School of Clinical and Experimental Medicine, College of Medical and Dental Sciences, University of Birmingham, UK; Doctoral Training Centre for Physical Sciences of Imaging in the Biomedical Sciences (PSIBS), University of Birmingham, UK.
  • Syeda F; Centre for Cardiovascular Sciences, School of Clinical and Experimental Medicine, College of Medical and Dental Sciences, University of Birmingham, UK.
  • Holmes AP; Centre for Cardiovascular Sciences, School of Clinical and Experimental Medicine, College of Medical and Dental Sciences, University of Birmingham, UK.
  • Osborne B; Centre for Cardiovascular Sciences, School of Clinical and Experimental Medicine, College of Medical and Dental Sciences, University of Birmingham, UK.
  • Dehghani H; Doctoral Training Centre for Physical Sciences of Imaging in the Biomedical Sciences (PSIBS), University of Birmingham, UK; School of Computer Science, College of Engineering and Physical Sciences, University of Birmingham, UK.
  • Brain KL; School of Clinical and Experimental Medicine, College of Medical and Dental Sciences, University of Birmingham, UK.
  • Kirchhof P; Centre for Cardiovascular Sciences, School of Clinical and Experimental Medicine, College of Medical and Dental Sciences, University of Birmingham, UK.
  • Fabritz L; Centre for Cardiovascular Sciences, School of Clinical and Experimental Medicine, College of Medical and Dental Sciences, University of Birmingham, UK. Electronic address: L.Fabritz@bham.ac.uk.
Prog Biophys Mol Biol ; 115(2-3): 340-8, 2014 Aug.
Article em En | MEDLINE | ID: mdl-25130572
ABSTRACT
We developed and validated a new optical mapping system for quantification of electrical activation and repolarisation in murine atria. The system makes use of a novel 2nd generation complementary metal-oxide-semiconductor (CMOS) camera with deliberate oversampling to allow both assessment of electrical activation with high spatial and temporal resolution (128 × 2048 pixels) and reliable assessment of atrial murine repolarisation using post-processing of signals. Optical recordings were taken from isolated, superfused and electrically stimulated murine left atria. The system reliably describes activation sequences, identifies areas of functional block, and allows quantification of conduction velocities and vectors. Furthermore, the system records murine atrial action potentials with comparable duration to both monophasic and transmembrane action potentials in murine atria.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potenciais de Ação / Reconhecimento Automatizado de Padrão / Fotografação / Imagens com Corantes Sensíveis à Voltagem / Sistema de Condução Cardíaco / Condução Nervosa Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Potenciais de Ação / Reconhecimento Automatizado de Padrão / Fotografação / Imagens com Corantes Sensíveis à Voltagem / Sistema de Condução Cardíaco / Condução Nervosa Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2014 Tipo de documento: Article