Your browser doesn't support javascript.
loading
Numerical investigation of the effect of stenosis geometry on the coronary diagnostic parameters.
Kamangar, Sarfaraz; Kalimuthu, Govindaraju; Badruddin, Irfan Anjum; Badarudin, A; Ahmed, N J Salman; Khan, T M Yunus.
Afiliação
  • Kamangar S; Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
  • Kalimuthu G; Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
  • Badruddin IA; Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
  • Badarudin A; Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
  • Ahmed NJ; Faculty of Engineering & Technology, Multimedia University, 75450 Bukit Beruang, Malacca, Malaysia.
  • Khan TM; Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
ScientificWorldJournal ; 2014: 354946, 2014.
Article em En | MEDLINE | ID: mdl-25258722
The present study deals with the functional severity of a coronary artery stenosis assessed by the fractional flow reserve (FFR). The effects of different geometrical shapes of lesion on the diagnostic parameters are unknown. In this study, 3D computational simulation of blood flow in three different geometrical shapes of stenosis (triangular, elliptical, and trapezium) is considered in steady and transient conditions for 70% (moderate), 80% (intermediate), and 90% (severe) area stenosis (AS). For a given percentage AS, the variation of diagnostic parameters which are derived from pressure drop across the stenosis was found in three different geometrical shapes of stenosis and it was observed that FFR is higher in triangular shape and lower in trapezium shape. The pressure drop coefficient (CDP) was higher in trapezium shape and lower in triangular model whereas the LFC shows opposite trend. From the clinical perspective, the relationship between percentage AS and FFR is linear and inversely related in all the three models. A cut-off value of 0.75 for FFR was observed at 76.5% AS in trapezium model, 79.5% in elliptical model, and 82.7% AS for the triangular shaped model. The misinterpretation of the functional severity of the stenosis is in the region of 76.5%-82.7 % AS from different shapes of stenosis models.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Estenose Coronária / Modelos Anatômicos / Modelos Cardiovasculares Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Estenose Coronária / Modelos Anatômicos / Modelos Cardiovasculares Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article