Your browser doesn't support javascript.
loading
A randomized direct comparison of the pharmacokinetics and pharmacodynamics of apixaban and rivaroxaban.
Frost, Charles; Song, Yan; Barrett, Yu Chen; Wang, Jessie; Pursley, Janice; Boyd, Rebecca A; LaCreta, Frank.
Afiliação
  • Frost C; Exploratory Clinical and Translational Research, Bristol-Myers Squibb Company, Princeton, NJ, USA.
  • Song Y; Exploratory Clinical and Translational Research, Bristol-Myers Squibb Company, Princeton, NJ, USA.
  • Barrett YC; Exploratory Clinical and Translational Research, Bristol-Myers Squibb Company, Princeton, NJ, USA.
  • Wang J; Exploratory Development Global Biometric Sciences, Bristol-Myers Squibb Company, Princeton, NJ, USA.
  • Pursley J; Analytical and Bioanalytical Development, Bristol-Myers Squibb Company, Princeton, NJ, USA.
  • Boyd RA; Global Innovative Pharma Business Clinical Pharmacology, Pfizer Inc., Groton, CT, USA.
  • LaCreta F; Exploratory Clinical and Translational Research, Bristol-Myers Squibb Company, Princeton, NJ, USA.
Clin Pharmacol ; 6: 179-87, 2014.
Article em En | MEDLINE | ID: mdl-25419161
ABSTRACT

BACKGROUND:

Currently, there are no direct comparisons of apixaban and rivaroxaban, two new oral direct factor Xa inhibitors approved for management of thromboembolic disorders.

OBJECTIVE:

Compare the pharmacokinetics and anti-factor Xa activity (AXA) of apixaban and rivaroxaban.

METHODS:

In this randomized, open-label, two-period, two-treatment crossover study, healthy subjects (N=14) received apixaban 2.5 mg twice daily (BID) and rivaroxaban 10 mg once daily (QD) for 4 days with a ≥4.5-day washout. Plasma samples were obtained for pharmacokinetic and AXA assessments; parameters were calculated using noncompartmental methods.

RESULTS:

Median time-to-maximum concentration was 2 hours for both compounds, and the mean half-life was 8.7 and 7.9 hours for apixaban and rivaroxaban, respectively. Daily exposure, the area under the curve (AUC(0-24)), appeared similar for rivaroxaban (1,094 ng · h/mL) and apixaban (935 ng · h/mL), whereas mean peak-to-trough plasma concentration ratio was 3.6-fold greater for rivaroxaban (16.9) than apixaban (4.7). Coefficient of variation for exposure parameters (AUC0-24, Cmax, Cmin) was 20%-24% for apixaban versus 29%-46% for rivaroxaban. Peak AXA, AXA AUC(0-24), and AXA fluctuation were ~2.5-, 1.3-, and 3.5-fold higher for rivaroxaban than apixaban, respectively. Trough concentrations and AXA were lower for rivaroxaban (10 ng/mL and 0.17 IU/mL vs 17 ng/mL and 0.24 IU/mL for apixaban, respectively). Rivaroxaban exhibited a steeper concentration-AXA response (slope 0.0172 IU/ng vs 0.0134 IU/ng for apixaban, P<0.0001).

CONCLUSION:

Apixaban 2.5 mg BID demonstrated less intersubject variability in exposure, lower AXA AUC, and higher trough and smaller peak-to-trough fluctuations in plasma concentration and AXA, suggesting more constant anticoagulation compared with rivaroxaban 10 mg QD. However, the clinical impact of these differences on the relative efficacy and safety of apixaban and rivaroxaban remains to be determined.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Prognostic_studies Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Prognostic_studies Idioma: En Ano de publicação: 2014 Tipo de documento: Article