Your browser doesn't support javascript.
loading
Pulp chamber temperature increase from curing light units: an in vitro study.
Cantekin, Kenan; Buyuk, Suleyman Kutalmis; Delikan, Ebru; Pedük, Kübra; Demirbuga, Sezer.
Afiliação
  • Cantekin K; Department of Pediatric Dentistry, Faculty of Dentistry, Erciyes University, Kayseri, Turkey. k_cantekin@hotmail.com.
  • Buyuk SK; Department of Orthodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.
  • Delikan E; Department of Pediatric Dentistry, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.
  • Pedük K; Department of Pediatric Dentistry, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.
  • Demirbuga S; Department of Restorative Dentistry, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.
J Dent Child (Chic) ; 81(3): 128-32, 2014.
Article em En | MEDLINE | ID: mdl-25514256
ABSTRACT

PURPOSE:

The purpose of this study was to compare temperature rises in the pulp chamber induced by halogen, plasma arc, and conventional light-emitting diode (LED) curing units with that induced via a new generation LED-curing unit (VALO) in extra power mode.

METHODS:

A Class I cavity was prepared on the occlusal surface of 80 extracted caries- free mandibular third molars, which were filled with a microhybrid composite. A thermocouple wire was inserted into the pulp chamber of each tooth to measure temperature changes.

RESULTS:

The greatest temperature increases were observed during polymerization of composite resin with a halogen curing unit (3.2 degrees Celsius), followed by plasma arc curing (2.07 degrees Celsius) and VALO curing (1.44 degrees Celsius); the lowest temperature rise was with conventional LED curing (1.01 degrees Celsius).

CONCLUSION:

There were no statistically significant differences between conventional LED and VALO curing in extra power mode regarding pulp chamber temperature increases when polymerizing composite resin.