Your browser doesn't support javascript.
loading
Myocardial perfusion imaging parameters: IQ-SPECT and conventional SPET system comparison.
Havel, Martin; Kolacek, Michal; Kaminek, Milan; Dedek, Vladimir; Kraft, Otakar; Sirucek, Pavel.
Afiliação
  • Havel M; Department of Nuclear Medicine, University Hospital Ostrava, Ostrava, 708 52, Czech Republic. havel.martin@gmail.com.
Hell J Nucl Med ; 17(3): 200-3, 2014.
Article em En | MEDLINE | ID: mdl-25526755
ABSTRACT
Technological advancement in hardware and software development in myocardial perfusion imaging (MPI) leads to the shortening of acquisition time and reduction of the radiation burden to patients. We compared semiquantitative perfusion results and functional parameters of the left ventricle between new dedicated cardiac system with astigmatic collimators called IQ-SPECT (Siemens Medical Solutions, USA) and conventional single photon emission tomography (SPET) system equipped with standard low energy high resolution collimators. A group of randomly selected 81 patients underwent consecutively the MPI procedure on IQ-SPECT and on conventional SPET systen, both without attenuation correction. The summed scores and the values of the functional parameters of the left ventricle ejection fraction (EF), end-systolic and end-diastolic volumes (ESV, EDV) received from the automatic analysis software were compared and statistically analyzed. Our results showed that summed scores values were significantly higher for the IQ-SPECT system in comparison to the conventional one. Calculated EF were significantly lower for IQ-SPECT, whereas evaluated left ventricular volumes (LVV) were significantly higher for this system. In conclusion, we recorded significant differences in automatically calculated semiquantitative perfusion and functional parameters when compared uncorrected studies obtained by the IQ-SPECT with the conventional SPET system.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Doença da Artéria Coronariana / Aumento da Imagem / Tomografia Computadorizada de Emissão de Fóton Único / Disfunção Ventricular Esquerda / Técnicas de Imagem de Sincronização Cardíaca / Imagem de Perfusão do Miocárdio Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Doença da Artéria Coronariana / Aumento da Imagem / Tomografia Computadorizada de Emissão de Fóton Único / Disfunção Ventricular Esquerda / Técnicas de Imagem de Sincronização Cardíaca / Imagem de Perfusão do Miocárdio Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article